Technical data • Entire device
Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
2.13.7 Status LEDs CAN / X2X (only APC620 embedded)
2.13.8 POWERLINK (only APC620 embedded)
Driver support
The fieldbus interface POWERLINK is only supported together with Automation Runtime.
Status / Error LED
The status/error LED is a green/red dual LED. The color green (status) is superimposed on the
color red (error).
Status LEDs CAN / X2X (only APC620 embedded)
Yellow LED for
On
Off
CAN
Sends data
Receives data
X2X
Sends data
Receives data
Table 36: Status LEDs CAN / X2X (only APC620 embedded)
POWERLINK (only APC620 embedded)
Controller
Cabling
S/STP (Cat5e)
Transfer rate
Cable length
max. 100 m (min. Cat5e)
LED color
On
Off
Green/red
see Status / Error LED
Green
Link
(POWERLINK
network
connection
available)
Activity (blinking)
(Data transfer in
progress)
Table 37: POWERLINK (only APC620 embedded)
Red - error
Description
On
The POWERLINK interface has encountered an error (failed Ethernet frames, increased number of
collisions on the network, etc.).
Table 38: Status / Error LED as error LED - POWERLINK V2 operating mode
green/red
green
Status/Error LED
Summary of Contents for Automation PC 620
Page 2: ...2 Automation PC 620 with 945GME N270 CPU board User s Manual V 1 10 ...
Page 4: ...4 Automation PC 620 with 945GME N270 CPU board User s Manual V 1 10 ...
Page 6: ...6 Automation PC 620 with 945GME N270 CPU board User s Manual V 1 10 ...
Page 568: ...568 Appendix A Glossary Automation PC 620 with 945GME N270 CPU board User s Manual V 1 10 ...