Control Wiring 5-5
MN762S
P1-08
Digital In 1
(Term 2)
Digital In 2
(Term 3)
Digital In 3
(Term 4)
Analog Input
(Term 6)
17
Normally
Open (NO)
Normally Closed (NC)
Normally Open (NO)
Open: Preset Speed 1
Momentarily
Close to Run
Fwd
Momentarily Open to
Stop
Momentarily Close to Run Rev
Closed: Keypad
Speed
18
Open: Stop
Closed: Run
Digital Input 2
Digital Input 3
Preset Speed
Ref
Open: Preset Speed
Closed: Keypad
Speed
Open
Open
Preset Speed 1
Closed
Open
Preset Speed 2
Open
Closed
Preset Speed 3
Closed
Closed
Preset Speed 4
19
Open: Stop
Open : Bipolar analog
speed ref
Analog input 2
Bipolar analog input
Closed: Run
Closed : Analog input 2
speed ref
20
Open: Stop
Digital Output:
Open: Bipolar analog speed ref
Bipolar analog input
Closed: Run
Drive Healthy = +24V
Closed: Preset Speed 1
21
Open: Stop
Digital Output:
Open: Forward
Bipolar analog input
Closed: Run
Drive Healthy = +24V
Closed: Reverse
22
Open: Stop
Digital Output:
Open: Trip
Bipolar analog input
Closed: Run
Drive Healthy = +24V
Closed: No Trip
Notes:
Negative Preset Speeds will be inverted if Run Reverse is selected.
The external trip input can be used to connect a motor thermistor between terminals 1 and 4.
When P1-07 = 0, P2-01 = 4 and P4-06 < > 2, Analog Input 2 is used for the speed reference.
When P1-07 = 0, P2-01 = 4 and P4-06 = 2, Bipolar Analog Input is used for the speed reference and Analog
Input 2 becomes the torque reference.
Table 5-3 Parameter P1-08 Control of Digital Inputs when P1-07=0 Continued
Summary of Contents for VS1MXS51
Page 1: ...03 11 Installation Operating Manual MN762S VS1MXS AC Extreme Duty Microdrive...
Page 28: ...5 10 Control Wiring MN762S...
Page 58: ...7 24 Parameter Descriptions MN762S...
Page 60: ...8 2 Customizing Your Application MN762S...
Page 80: ...D 2 Options and Kits MN762S...
Page 85: ......
Page 86: ......