P4-08
Minimum torque limit 0.0 to 150.0
%
0.0
Sets a minimum torque
limit, see the warning
below.
P4-09
V/f characteristic
adjustment
frequency
0 to P1-03
Hz
0.0
When operating in V/f
mode (P4-01 = 2), sets a
frequency point at which
the voltage applied in
P4-10 is applied to the
motor. Care must be taken
to avoid overheating and
damaging the motor when
using this feature.
P4-10
V/f characteristic
adjustment voltage
0 to P1-01
-
0
In conjunction with P4-09,
in V/f mode (P4-01 = 2),
sets the voltage applied
to the motor at the
adjustment frequency set
in P4-09.