B-8 Parameter Tables
MN762S
Param
#
Access
Parameter Name
Description (Range)
Factory
Setting
User
Setting
P6-02
RW
Thermal Management
Enable
0: Disable
1: Enable
0
P6-03
RW
Auto-Reset Delay Time
1s…60
20
P6-04
RW
User Relay Speed
Hysteresis Band
0.0 … 25.0
0.3
P6-05
RW
Encoder Feedback
Enable
0: Disabled
1: Enabled
0
P6-06
RW
Encoder PPR
0 .. 10000
0
P6-07
RW
Encoder Speed Error
Limit
0.0 … 50.0
5.0
P6-08
RW
Modbus
Communication Loss
Timer
0: disabled
1..60
2
P6-09
RW
Speed Droop Control
0.0 …25.0% of P1-03
0
P6-10
RW
Brake Chopper Duty
Cycle when Under
Temperature
0.0…20.0
2.0
P6-11
RW
Preset Speed Run Time
On Enable
0.0..600.0
0.0
P6-12
RW
Preset Speed Run Time
on Disable
0.0..600.0
0.0
Table B-1 Parameters Sorted by Parameter Number Continued