Parameter Descriptions 7-9
MN762S
Par No.
Description
Range
Units
Default
Explanation
P2-33
2nd analog
input format
= Digital
=
0 to 10V DC
=
4 to 20mA
=
0 to 20mA
-
Selects the format for the 2nd
analog input
Selecting
sets the input
up as a digital input.
P2-34
2nd analog
input scaling
0 to 500.0
%
100.0
Scales the 2nd analog input by
the factor set in this parameter.
P2-35
Digital speed
reference
scaling control
0: Disabled (No
Scaling)
1: Scaled by
P2-29
2: Scaled by
P2-29, then
bipolar analog
input added
as an offset
3: Scaled by
P2-29 and by
bipolar analog
input
-
0
Active in Keypad mode (P1-07 =
1 or 2) and Master / Slave mode
only.
1: Actual Speed = Digital Speed
x P2-29
2: Actual Speed = (Digital
Speed x P2-29) + bipolar
analog reference
3: Actual Speed = Digital
Speed x P2-29 x bipolar
analog reference
P2-36
Analog output
format
=
0 to 10V
=
4 to 20mA
=
10 to 0V
=
20 to 4mA
-
Selects the analog output signal
format.
P2-37
Extended menu
access code
0 to 9999
-
101
Defines the access code which
must be entered in P1-14 to
access parameter groups above
Group 1.
P2-38
Parameter Lock
0: Unlocked
1: Locked
-
0
When locked, all parameter
changes are prevented.
P2-39
Hours Run
Counter
0 to 99999
Hours
Read
Only
Indicates the number of hours for
which the drive has run.
P2-40
Drive Type /
Rating
N/A
-
Read
Only
Read only parameter, showing
the drive type and power rating.
Table 7-2 Parameter Group 2 - Extended Parameters Continued
Summary of Contents for VS1MXS51
Page 1: ...03 11 Installation Operating Manual MN762S VS1MXS AC Extreme Duty Microdrive...
Page 28: ...5 10 Control Wiring MN762S...
Page 58: ...7 24 Parameter Descriptions MN762S...
Page 60: ...8 2 Customizing Your Application MN762S...
Page 80: ...D 2 Options and Kits MN762S...
Page 85: ......
Page 86: ......