Parameter Tables B-3
MN762S
Param
#
Access
Parameter Name
Description (Range)
Factory
Setting
User
Setting
P0-56
RO
Droop Speed
Internal value
Read Only
P0-57
RO
Encoder Speed
-P1-06 to P1-06
Read Only
P0-58
RO
Speed Jump Zone
Internal value
Read Only
P0-59
RO
Modbus Write
Command Data Value
Register dependent
Read Only
P0-60
RO
Motor Control Loop ID
0 … 65535
Read Only
P1-01
RW
Motor Rated Voltage
0, 20 to 600
575
P1-02
RW
Motor Rated Current
25% -100% of drive rated
current
Drive
rating
P1-03
RW
Motor Rated Frequency
25Hz to 2000Hz
60
P1-04
RW
Motor Rated Speed
0 to 60000 rpm
0
P1-05
RW
Minimum Frequency /
Speed
0.0 to P1-06
0.0
P1-06
RW
Maximum Freq. / Speed P1-05 to 5*P1-03 (max 2000Hz)
60.0
P1-07
RW
Terminal / Keypad / PID
Drive Control Mode
Selection
0: Terminal control
1: Keypad control – fwd only
2: Keypad control – fwd and rev
3: PID Control
4: Modbus RTU Control
0
P1-08
RW
Digital Input Function
Select
0 to 22
0
P1-09
RW
Stop Mode Select
0 : Ramp to stop
1 : Coast to stop
2 : Ramp to stop with ‘fast stop’
0
P1-10
RW
Acceleration Ramp
Time
0.0 to 3000.0
5.0
P1-11
RW
Deceleration Ramp
Time
0.0 to 3000.0
5.0
P1-12
RW
Energy Optimizer
0: Disabled 1: Enabled
0
P1-13
RO
Trip Log
Last four trips stored
Read only
P1-14
RW
Extended Menu Access Code 0 to 30000
0
P2-01
RW
Preset Speed 1
-P1-06 to P1-06
50.0
(60.0)
P2-02
RW
Preset Speed 2
-P1-06 to P1-06
0.0
P2-03
RW
Preset Speed 3
-P1-06 to P1-06
0.0
P2-04
RW
Preset Speed 4
-P1-06 to P1-06
0.0
P2-05
RW
Preset Speed 5
-P1-06 to P1-06
0.0
P2-06
RW
Preset Speed 6
-P1-06 to P1-06
0.0
P2-07
RW
Preset speed 7
-P1-06 to P1-06
0.0
Table B-1 Parameters Sorted by Parameter Number Continued
Summary of Contents for VS1MXS51
Page 1: ...03 11 Installation Operating Manual MN762S VS1MXS AC Extreme Duty Microdrive...
Page 28: ...5 10 Control Wiring MN762S...
Page 58: ...7 24 Parameter Descriptions MN762S...
Page 60: ...8 2 Customizing Your Application MN762S...
Page 80: ...D 2 Options and Kits MN762S...
Page 85: ......
Page 86: ......