Parameter Tables B-1
MN762S
Appendix B
Parameter Tables
B.1 Parameters Sorted by Parameter Number
Table B-1 Parameters Sorted by Parameter Number
Param
#
Access
Parameter Name
Description (Range)
Factory
Setting
User
Setting
P0-01
RO
Bipolar Analog Input
Value
-100 to 100
Read Only
P0-02
RO
2nd Analog Input Value
0 to 100
Read Only
P0-03
RO
Post Ramp Speed
Reference
-500 to 500
Read Only
P0-04
RO
Digital Speed Reference -P1-06 to P1-06
Read Only
P0-05
RO
Torque Controller
Reference
0 to 200
Read Only
P0-06
RO
PID Reference
0 to 100
Read Only
P0-07
RO
PID Feedback
0 to 100
Read Only
P0-08
RO
PID Error
0 to 100
Read Only
P0-09
RO
PID P Term
0 to 100
Read Only
P0-10
RO
PID I Term
0 to 100
Read Only
P0-11
RO
PID D Term
0 to 100
Read Only
P0-12
RO
PID Output
0 to 100
Read Only
P0-13
RO
Output Torque
0 to 200
Read Only
P0-14
RO
Magnetizing Current
Drive dependent
Read Only
P0-15
RO
Rotor Current
Drive dependent
Read Only
P0-16
RO
Field Strength
0 to 100
Read Only
P0-17
RO
Stator Resistance
Drive dependent
Read Only
P0-18
RO
Stator Inductance
Drive dependent
Read Only
P0-19
RO
Rotor Resistance
Drive dependent
Read Only
P0-20
RO
DC Bus Voltage
0 to 1000
Read Only
P0-21
RO
Drive Temperature
0 to 120
Read Only
P0-22
RO
Supply Voltage L1 – L2
Drive dependent
Read Only
P0-23
RO
Supply Voltage L2 – L3
Drive dependent
Read Only
P0-24
RO
Supply Voltage L3 – L1
Drive dependent
Read Only
P0-25
RO
Estimated Rotor Speed
Drive dependent
Read Only
P0-26
RO
kWh Meter
0 to 999.9
Read Only
P0-27
RO
MWh Meter
0 to 60,000
Read Only
P0-28
RO
Software ID –
IO Processor
Drive dependent
Read Only
Summary of Contents for VS1MXS51
Page 1: ...03 11 Installation Operating Manual MN762S VS1MXS AC Extreme Duty Microdrive...
Page 28: ...5 10 Control Wiring MN762S...
Page 58: ...7 24 Parameter Descriptions MN762S...
Page 60: ...8 2 Customizing Your Application MN762S...
Page 80: ...D 2 Options and Kits MN762S...
Page 85: ......
Page 86: ......