90
14.6.14
PILOT (19kHz Pilot Stereo level)
This page allows the user to set mainly
the minimum and the maximum threshold
level for the Stereo Pilot, for each
single Channel / Frequency. With this alarm status variable (using a window zone) it is possible to monitor the pilot level
inside a nominal window zone and if it falls under a minimum level or monitor two low levels zones like RF levels.
NAME
DESCRIPTION
NOTE
Chan
Channel Number
Chan Label
Mnemonic name that can be applied to the Channel / Frequency
Frequency
Frequency corresponding to the Channel, expressed in MHz
Preset
String used by the configurator
Scan Time
This value represents the time in s that the tuner remain on this frequency.
Chan Mask
This control allow (or not) the channel to be under control.
If it is masked,
the channel is
NOT under
control
Min. Thr
Minimum Threshold level for the Pilot Stereo 19kHz. The value set here is the
minimum deviation level that the Pilot Stereo 19kHz carrier can reach. By default the
level is 5kHz. With a double click on the box can be changed by inserting the
desired value.
See Note1
reported
below
Max. Thr
Maximum Threshold level for the Pilot Stereo 19kHz. The value set here is the
maximum deviation level that the Pilot Stereo 19kHz carrier can reach. By default
the level is 8kHz. With a double click on the box can be changed by inserting the
desired value.
See Note2
reported
below
Hysteresis level
this value can be set as range of Hysteresis for the measurement. Hysteresis is the
dependence of a system not only on its current environment but also on its past
environment.
Validation
This field contains the time of persistence necessary to the alarm to be considered
“validated”. For example, if the system launches an alarm, this alarm must remain
“up” or “Active” for all the time of "Validation" to be considered a true alarm to avoid
the detection of spikes.
Hold
It is the time between the cessation of the alarm condition and alarm signaling
finished
Mask
It is possible to set, for each single parameter: unmasked, masked, severity-1,
severity-2, severity-3, RFL2 mask.
Email
In case the alarm/error raise up, the Wolf 2MS sends an email if <enable>.
If is <disable> no action are taken.
Summary of Contents for WOLF 1MS
Page 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Page 10: ...ENG GENERAL DESCRIPTION 10...
Page 11: ...ENG GENERAL DESCRIPTION 11...
Page 12: ...ENG GENERAL DESCRIPTION 12...
Page 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Page 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Page 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Page 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Page 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Page 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...