RF-H2 Monitor test (Tuner-1 Tuner-2)
An RF combined signal with one or more frequencies are applied to the tuner1 and/or tuner2 RF inputs. One carrier RF
level will be varied to test the alarms the other ones will be used to fill the scanning list. We have used 100.80MHz (RF
sweeping) and 100.50MHz(RF stable).
By slowly changing the the RF levels (in compatible way with the Validation and Hold time chosen) around the test zone,
wait for the alarms and go back up to the starting point.
Tested in Static mode first.
In static mode the alarm rises up after the validation time, a trap will be sent when the status variable changes but with
the time and the RF value of the first sample out of the range. When the RF level is lower or equal to THR- Hysteresis,
the status alarm after the hold time comes back to the (ok) state and another trap will be sent with the RF value and the
time of the first valid sample.
We have tested in static mode with the following values:
Thr: +110dBuV, Hyst: +3dBuV, Validation:2sec, Hold:2Sec
Thr: +110dBuV, Hyst: +3dBuV, Validation:20sec, Hold:10Sec
Thr: +110dBuV, Hyst: +3dBuV, Validation:180sec, Hold:60Sec
The behavior observed has been compatible with the definition with an accuracy error on the measure of about 2 dBuV
and timing errors of about 1-2 seconds
Typical Accuracy and Precision expected in general:
Min RF value readable : -6 dBuV, Max RF value readable: +123 dBuV
Accuracy: +-3 dBuV, Precision +-2 dBuV (Range -6 dBuV to +19 dBuV)
Accuracy: +-2 dBuV, Precision +-1 dBuV (Range +20 dBuV to +79 dBuV)
Accuracy: +-3 dBuV, Precision +-3 dBuV (Range +80 dBuV to +123 dBuV)
Under the alarm condition the RF alarm led on the panel must be on (not flashing) and clicking on the channel number of
the correspondent tuner the RF erro
r will be displayed. (“RF_LEV_H2”)
Summary of Contents for WOLF 1MS
Page 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Page 10: ...ENG GENERAL DESCRIPTION 10...
Page 11: ...ENG GENERAL DESCRIPTION 11...
Page 12: ...ENG GENERAL DESCRIPTION 12...
Page 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Page 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Page 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Page 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Page 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Page 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...