TECHNICAL APPENDIX
| TECHNICAL APPENDIX
190
The traps will be sent in the instant the alarm rises up, but CT and the time in the var-binds will be related to the first
failed check.
Under the alarm condition the RDS alarm led on the panel must be on (flashing if the alarms are more than one on the
channel list) and clicking on the channel number of the correspondent tuner the RDS error
will be displayed (“RDS
DATA”).
In case of more errors on the related channel, they will rotate for about 30 seconds in a sequence carousel.
For a second branch of tests we have set Timeout to 130 sec. and stopped Radio CT transmission (no 4A groups was
broadcasted).
We have performed the same tests in Static Mode, Scan Mode and Smart Scan Mode as above, checking front panel
visualization and leds, alarms and traps.
We’ve obtained the same behaviors of Test 1 with the only difference on CT alarm description:
Summary of Contents for WOLF 1MS