75
It is possible to set for each single parameter under control the Masked or unmasked and the Severity Level on these
value:
RFL2
–
RFL1
/
RFH1
–
RFH2
–
DEV
–
PILOT Low
– PILOT – RDS Low – RDS – AUDIO Dev - AUDIO Left – AUDIO
Right
–AUDIO Ms - AUDIO Si - PI
–
PS
–
TP
-
TA
–
CT
–
RT
–
AF
–
EON
– IH -
TMC
–
RT+
-
ODA1
–
ODA2
–
BLER
in the column
MASK
.
14.6.7
The meaning of “Mask” on each single parameter under control
On each single parameter under control it is also possible to set the if the single parameter can be Masked, unmasked,
Severity1
– Severity2 – Severity3 or RFL2. In this case each single parameter follow an Individual Masking.
The severity level is generally assigned in order to have a relation between the parameter under control and the priority.
All the parameters involved in Severity1
– Severity2 – Severity3 can be masked or not.
Masked
Alarm
IS
masked (if
Global Tuner Mask Mode
is set in individual masking)
Unmasked
Alarm
IS NOT
masked (if
Global Tuner Mask Mode
is set in individual masking)
Severity-1
The Alarm is masked only if
Global Tuner Mask Mode
is set on a Severity
<
or
equal
to 1 (it means always not masked)
Severity-2
The Alarm is masked only if
Global Tuner Mask Mode
is set on a Severity
<
or
equal
to 2
Severity-3
The Alarm is masked only if
Global Tuner Mask Mode
is set on a Severity
<
or
equal
to 3 (it means always masked)
RFL2 Mask
Masked if the Alarm RFL2 Mask is active.
(see Note2 below)
Note1
: it is not possible to mix the (
Severity1
-
Severity2
-
Severity3
) with
Individual Masking
Note2
: in order to work properly the RFL2 Mask requires that validation is less of RFL2 and Hold time is greater than the
individual alarms that use this type of mask.
Summary of Contents for WOLF 1MS
Page 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Page 10: ...ENG GENERAL DESCRIPTION 10...
Page 11: ...ENG GENERAL DESCRIPTION 11...
Page 12: ...ENG GENERAL DESCRIPTION 12...
Page 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Page 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Page 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Page 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Page 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Page 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...