104
Label
This is the label/content that the user can choose to shows via email or in the trap in
case of error.
Note1
There is no control check on input field. Please pay attention to the correct typing.
So, for example, a PI Ref. 5*00 will match with 5000, 5100, 5200, etc.
It is possible to replace more than one field at a time (up to all!).
An example: PI Ref: 5*** matches with PI values from 5000 up to 5FFF.
Example:
The PI Code can be Ref1 or Ref2. If a PI Code is different from Ref1 and Ref2 and alarm is generated.
This setting is usefull to broadcaster that change the PI Code during regional broadcasting.
Note2
It is possible to replace any of the four digits of PI fields with a wildcard (represented with an asterisk).
So, for example, a PI Ref. 5*00 will match with 5000, 5100, 5200, etc.
It is possible to replace more than one field at a time (up to all!).
An example: PI Ref: 5*** matches with PI values from 5000 up to 5FFF.
Please focus on comparison mechanism: received PI will be compared first with RefMask1 and then with RefMask2, so
this case:
Ref1=5*02 Ref2=54*2 PI=5712
raise an alarm, but
Ref1=5**2 Ref2=1234 PI=5712
matches.
Note3
The PI Code can be compared with Ref1 or Ref2. If a PI Code is different from Ref1 and Ref2 and alarm is generated.
This setting is useful to broadcaster that change the PI Code during regional broadcasting.
Note4
If a Reference is empty no comparison with received PI occurs but only other RefMask is taken into account for a match.
If each Reference Mask are empty no comparison with PI occurs at all.
Summary of Contents for WOLF 1MS
Page 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Page 10: ...ENG GENERAL DESCRIPTION 10...
Page 11: ...ENG GENERAL DESCRIPTION 11...
Page 12: ...ENG GENERAL DESCRIPTION 12...
Page 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Page 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Page 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Page 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Page 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Page 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...