134
14.3 ANALOG AUDIO INPUT SETUP
The following setup is about the Analog Input Module, alarms generation and configurable settings. The A.A.L means
Audio Analog Left while A.A.R means Audio Analog Right.
Audio Analog Left Silence Trap Label:
define
the Trap label over the NMS manager.
A.A.L.Silence Threshold:
defines the threshold
level to be considered audio or silence.
A.A.L.Silence Time:
defines the maximum time
under A.A.L.Silence Threshold to consider the
input audio not valid (as silence)
A.A.L.Silence Hold:
It’s the time in which the
audio signal must be stably present to be
considered valid.
A.A.L.Silence Mask:
if this parameter is Mask the
silence error is not reported, while unmasked
means the error is visible and reported.
A.A.L.Silence Email Enabled
: this parameter
enable the email sending in case of silence error.
A.A.L.Silence Trap Enabled
: this parameter
enable the Trap sending in case of silence error.
Audio Analog Right Silence Trap Label:
define
the Trap label over the NMS manager.
A.A.R.Silence Threshold:
defines the threshold
level to be considered audio or silence.
A.A.R.Silence Time:
defines the maximum time
under A.A.R.Silence Threshold to consider the
input audio not valid (as silence)
A.A.R.Silence Hold:
It’s the time in which the
audio signal must be stably present to be
considered valid.
A.A.R.Silence Mask:
if this parameter is Mask
the silence error is not reported, while unmasked
means the error is visible and reported.
A.A.R.Silence Email Enabled
: this parameter
enable the email sending in case of silence error.
A.A.R.Silence Trap Enabled
: this parameter
enable the Trap sending in case of silence error.
Summary of Contents for WOLF 1MS
Page 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Page 10: ...ENG GENERAL DESCRIPTION 10...
Page 11: ...ENG GENERAL DESCRIPTION 11...
Page 12: ...ENG GENERAL DESCRIPTION 12...
Page 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Page 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Page 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Page 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Page 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Page 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...