113
14.6.31
RDS AF (Alternative Frequency)
For Alternative Frequencies there is only a presence check.
If in the RDS there are no AF’s an error is reported.
NAME
DESCRIPTION
NOTE
Chan
Channel Number
Chan Label
Mnemonic name that can be applied to the Channel / Frequency
Frequency
Frequency corresponding to the Channel, expressed in MHz
Preset
String used by the configurator
Scan Time
This value represents the time in s that the tuner remain on this frequency.
Chan Mask
This control allow (or not) the channel to be under control.
If it is masked,
the channel is
NOT under
control
Validation
This field contains the time of persistence necessary to the alarm to be considered
“validated”. For example, if the system launches an alarm, this alarm must remain
“up” or “Active” for all the time of "Validation" to be considered a true alarm to avoid
the detection of spikes.
Hold
is the time between the cessation of the alarm condition and alarm signaling finished
Mask
It is possible to set, for each single parameter: unmasked, masked, severity-1,
severity-2, severity-3, RFL2 mask.
Email
In case the alarm/error raise up, the Wolf 2MS sends an email if <enable>.
If is <disable> no action are taken.
Trap
In case the alarm/error raise up, the Wolf 2MS sends a trap if <enable>.
If is <disable> no action are taken.
Label
This is the label/content that the user can choose to shows via email or in the trap in
case of error.
Summary of Contents for WOLF 1MS
Page 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Page 10: ...ENG GENERAL DESCRIPTION 10...
Page 11: ...ENG GENERAL DESCRIPTION 11...
Page 12: ...ENG GENERAL DESCRIPTION 12...
Page 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Page 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Page 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Page 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Page 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Page 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...