
TECHNICAL APPENDIX
| TECHNICAL APPENDIX
196
The traps will be sent in the instant the alarm rises up, but AF and the time in the var-binds will be related to the first
failed check.
Under the alarm condition the RDS alarm led on the panel must be on (flashing if the alarms are more than one on the
channel list) and clicking on t
he channel number of the correspondent tuner the RDS error will be displayed (“RDS
DATA”).
In case of more errors on the related channel, they will rotate for about 30 seconds in a sequence carousel.
In SmartScan Mode the behavior expected is the same of the normal Scanning mode because this parameter is
continuous and always available on the channel.
REPLAY ENABLED TRAPS
The Rds AF alarm trap are replayed with its original status, time and value. Trap Counter is normally incremented.
All data and parameters are available in the MIB L3-5 to set and test this configuration.
Summary of Contents for WOLF 1MS
Page 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Page 10: ...ENG GENERAL DESCRIPTION 10...
Page 11: ...ENG GENERAL DESCRIPTION 11...
Page 12: ...ENG GENERAL DESCRIPTION 12...
Page 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Page 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Page 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Page 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Page 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Page 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...