![Avermedia NX 8000 series User Manual Download Page 17](http://html1.mh-extra.com/html/avermedia/nx-8000-series/nx-8000-series_user-manual_3030011017.webp)
9
2.6 Sensor and Relay pinhole allocation on NX8000 series
i
NXU8000 series needs to purchase the E-I/O box for I/O connection.
The signal from the sensor (i.e., infrared sensors, smoke detectors, proximity sensors, door sensors,
etc.) is being transmitted to the I/O card, and this triggers the system to respond and send signal to
relay device (i.e., alarm, telephone etc).
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Pin #
Definition
Pin #
Definition
1
Sensor input signal 1+
11
Relay Normal Close 1
2
Sensor output signal 1-(GND)
12
Relay Common 2
3
Sensor input signal 2+
13
Relay Normal Open 2
4
Sensor output signal 2-(GND)
14
Relay Normal Close 2
5
Sensor input signal 3+
15
Relay Common 3
6
Sensor output signal 3-(GND)
16
Relay Normal Open 3
7
Sensor input signal 4+
17
Relay Normal Close 3
8
Sensor output signal 4-(GND)
18
Relay Common 4
9
Relay Common 1
19
Relay Normal Open 4
10
Relay Normal Open 1
20
Relay Normal Close 4
Summary of Contents for NX 8000 series
Page 1: ...AVerMedia NX8000 NXU8000 series User Manual April 2009...
Page 24: ......
Page 34: ...26 9 User can select the Date Camera and Cycle to view the report of object counts In Out...
Page 58: ...50 i The UPS application must meet Windows XP or Windows Vista system requirements...
Page 78: ...70 Region 1 Object size frame Region 2 Object counting information display...
Page 81: ...73...
Page 96: ...88 13 To view the all I O devices information click I O Map...
Page 199: ...191 4 Mark the UPnP Framework check box and click OK...