AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF
37
2.Specfication
Model
Indoor Unit
ALCF-H18/4R1C
ALCF-H24/4R1C
Outdoor Unit
AL-H18/4R1D(U)
AL-H24/4R1D(U)
Factory Model
Indoor Unit
ALCe-H18A4/R1C5-B7
ALCe-H24B4/R1C5-B7
Outdoor Unit
AL-H18A4/R1(T)-B7
AL-H24A4/R1(T)-B7
Factory Model
Indoor Unit
16109022000011
16109022000007
Outdoor Unit
16107022000019
16107022000018
Power Supply
V~,Hz,Ph
220~240,50,1
220~240,50,1
Capacity
Cooling
Btu/h
18000
24000
kW
5.3
7.2
Heating
Btu/h
20000
27500
kW
5.8
8.08
Electric Data
Rated Cooling Power
Input
kW
1.72
2.35
Rated Heating Power
Input
kW
1.77
2.40
Rated Cooling Current
A
7.9
10.09
Rated Heating Current
A
8.13
11.59
Performance
EER
W/W
3.08
3.06
COP
W/W
3.28
3.37
Indoor Fan Fotor
Model
YSK-40W-4
YSK-70W-4
Brand
Weiling
Weiling
Output Power x Fan
Quantity
W
40x1
70x1
Capacitor
uF
2.5
4
Speed (Hi/Mi/Lo)
r/min
1250/1100/900
1386/1108/970
Indoor Coil
Number Of Rows
3
3
Tube Pitch(a)x Row
Pitch(b)
mm
20.5×12.7
20.5×12.7
Fin Spacing
mm
1.6
1.6
Fin Material
Hydrophilic aluminum fin
Hydrophilic aluminum fin
Tube Outside Dia.and
Type
mm
φ7,Inner grooved
φ7,Inner grooved
Coil Length x Height x
Width
mm
599×246×38.1
950×246×38.1
Heat Exchanging Area
m
2
6.30
10.00
Indoor Unit
Indoor Air Flow
(Hi/Mi/Lo)
m
3
/h
850/680/595
1200/960/840
Noise Level(Hi/Mi/Lo)
dB(A)
43/40/34
46/43/38
Net Dimension
(W*H*D)
mm
929×660×205
1280×660×205
Packing Dimension
(W*H*D)
mm
1010×720×290
1360×720×290
Summary of Contents for AL-H12/4R1D
Page 4: ...AUX Light Commercial Air Conditioners T1 50Hz R410a ON OFF 4 1 Nomenclature ...
Page 72: ...AUX Light CAC 50Hz R410A Universal outdoor unit 72 ALMD H18 4R1D ALMD H24 4R1D ...
Page 93: ...AUX Light CAC 50Hz R410A Trouble shooting 93 1366 610 160 438 368 388 940 ...
Page 129: ...AUX Light CAC 50Hz R410A Trouble shooting 129 Outdoor protection phase sequence ...
Page 130: ...AUX Light CAC 50Hz R410A Trouble shooting 130 Cooling high pressure protection ...
Page 131: ...AUX Light CAC 50Hz R410A Trouble shooting 131 Heating high pressure protection ...
Page 132: ...AUX Light CAC 50Hz R410A Trouble shooting 132 Cooling low pressure protection ...
Page 133: ...AUX Light CAC 50Hz R410A Trouble shooting 133 Heating low pressure protection ...
Page 134: ...AUX Light CAC 50Hz R410A Trouble shooting 134 Cooling exhaust temperature protection ...
Page 135: ...AUX Light CAC 50Hz R410A Trouble shooting 135 Heating exhaust temperature protection ...
Page 137: ...AUX Light CAC 50Hz R410A Trouble shooting 137 Sensor failure protection ...
Page 138: ...AUX Light CAC 50Hz R410A Trouble shooting 138 No action after power on ...
Page 139: ...AUX Light CAC 50Hz R410A Trouble shooting 139 Poor effect ...
Page 140: ...AUX Light CAC 50Hz R410A Trouble shooting 140 ...
Page 141: ...AUX Light CAC 50Hz R410A Trouble shooting 141 Abnormal sound or viberation ...
Page 142: ...AUX Light CAC 50Hz R410A Trouble shooting 142 ...
Page 143: ...AUX Light CAC 50Hz R410A Trouble shooting 143 Abnormal odor ...
Page 145: ...AUX Light CAC 50Hz R410A Trouble shooting 145 Air conditioner water leakage ...