AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF
15
Model
Indoor
ALCA-H36/4R1E
Panel
MB12
Outdoor
AL-H36/4R1(U)
Factory Model
Indoor
ALCa-H36A4/R1-EA
Panel
MB12
Outdoor
AL-H36A4/R1(T)
Code
Indoor
16106021000005
Panel
16108002000007
Outdoor
16107022000001
Power Supply
V~,Hz,Ph
220~240,50,1
Capacity
Cooling
Btu/h
36000
KW
10.60
Heating
Btu/h
40000
KW
11.70
Electric Data
Rated Cooling Power
Input
KW
3.77
Rated Heating Power
Input
KW
3.50
Rated Cooling Current
A
17.3
Rated Heating Current
A
16.6
Performance
EER
W/W
2.81
COP
W/W
3.34
Indoor Fan Motor
Model
YDK45-6Q
Brand
WELLING/Sinjun
Output Power x Fan
quantity
W
45*1
Capacitor
uF
3
Speed (Hi/Mi/Lo)
r/min
650/520/450
Indoor Coil
Number Of Row
2
Tube Pitch(a)x Row
Pitch(b)
mm
20.5×12.7
Fin Pitch
mm
1.4
Fin Material
louver
Tube Outside Dia.and
Material
mm
φ7
,
Inner grooved
Coil Length x Height x
Width
mm
2014×205×25.4
Heat Exchanging Area
m
2
12.18
Indoor Unit
Indoor Air Flow
(Hi/Mi/Lo)
m
3
/h
1500/1200/1050
Noise Level(Hi/Mi/Lo)
dB(A)
48/45/39
Net Dimension
mm
835×835×250
Summary of Contents for AL-H12/4R1D
Page 4: ...AUX Light Commercial Air Conditioners T1 50Hz R410a ON OFF 4 1 Nomenclature ...
Page 72: ...AUX Light CAC 50Hz R410A Universal outdoor unit 72 ALMD H18 4R1D ALMD H24 4R1D ...
Page 93: ...AUX Light CAC 50Hz R410A Trouble shooting 93 1366 610 160 438 368 388 940 ...
Page 129: ...AUX Light CAC 50Hz R410A Trouble shooting 129 Outdoor protection phase sequence ...
Page 130: ...AUX Light CAC 50Hz R410A Trouble shooting 130 Cooling high pressure protection ...
Page 131: ...AUX Light CAC 50Hz R410A Trouble shooting 131 Heating high pressure protection ...
Page 132: ...AUX Light CAC 50Hz R410A Trouble shooting 132 Cooling low pressure protection ...
Page 133: ...AUX Light CAC 50Hz R410A Trouble shooting 133 Heating low pressure protection ...
Page 134: ...AUX Light CAC 50Hz R410A Trouble shooting 134 Cooling exhaust temperature protection ...
Page 135: ...AUX Light CAC 50Hz R410A Trouble shooting 135 Heating exhaust temperature protection ...
Page 137: ...AUX Light CAC 50Hz R410A Trouble shooting 137 Sensor failure protection ...
Page 138: ...AUX Light CAC 50Hz R410A Trouble shooting 138 No action after power on ...
Page 139: ...AUX Light CAC 50Hz R410A Trouble shooting 139 Poor effect ...
Page 140: ...AUX Light CAC 50Hz R410A Trouble shooting 140 ...
Page 141: ...AUX Light CAC 50Hz R410A Trouble shooting 141 Abnormal sound or viberation ...
Page 142: ...AUX Light CAC 50Hz R410A Trouble shooting 142 ...
Page 143: ...AUX Light CAC 50Hz R410A Trouble shooting 143 Abnormal odor ...
Page 145: ...AUX Light CAC 50Hz R410A Trouble shooting 145 Air conditioner water leakage ...