background image

5.1kW

 AIR 

CONDITIONER

SC-5100AU6A

INSTALLATION 

MANUAL

Please read this manual carefully before using, and keep it for future reference.

Summary of Contents for SC-5100AU6A

Page 1: ...5 1kW AIR CONDITIONER SC 5100AU6A INSTALLATION MANUAL Please read this manual carefully before using and keep it for future reference ...

Page 2: ......

Page 3: ...Safety 4 Selecting Installation Place 5 Installation of Indoor Unit 7 Installation of Outdoor Unit 9 Is the Unit Installed Correctly 14 Self Diagnosis Functions 15 Specifications 17 Customer Service 20 CONTENTS ...

Page 4: ...the fuse installed in the indoor unit is 3 15A 250V and outdoor unit is 20A 250V DO NOT INSTALL THE UNIT In environments where the air could contain gas oil or sulphur Near sources of heat At a distance of less than 50cm from flammable substances and pressurised containers If the appliance is used in areas without sufficient ventilation precautions must be taken to prevent any leaks of refrigerant...

Page 5: ... will be exposed to direct sunlight Do no install unit in the laundry Install the unit where connection between indoor and outdoor unit is easy Install unit where it is easy to drain condensation water Install unit where the filter can be easily accessed These installation instructions for the Air conditioner are for use by an appropriately qualified licensed installer Do not try to install the ai...

Page 6: ... sound level will not disturb neighbours Leave minimum clearences around the unit for free air circulation If the outdoor unit is vibrating place rubber gaskets on the feet of the unit The method of fixing is not to depend on the use of adhesives since they are not considered to be a reliable fixing means SELECTING INSTALLATION PLACE Cont MINIMUM DISTANCES FOR INSTALLATION ...

Page 7: ...ware not supplied 2 ACCESS TO PIPING Drill holes at places slightly below the wall mounting plate corresponding with where the piping and drain outlet exit the indoor unit with hole diameter of 65mm starting from the inside wall and make the outside wall 5 10mm lower so the water can smoothly flow out Cut the wall penetrating pipe to correct length according to the thickness of the wall and add 5m...

Page 8: ... hooks at the bottom of the indoor unit match the hook of the wall mounting plate 5 INSPECTIONS Check if the hooks on the mounting plate and unit at the top or bottom are firmly fixed Check that the indoor unit is properly level The drain pipe should not curve upward refer to picture below The drain pipe should be at the lower part of the wall pipes refer to below INSTALLATION OF INDOOR UNIT Cont ...

Page 9: ...Y PIPELINE CONNECTIONS AND AIR PURGING No dust foreign objects air or moisture should be allowed to enter the air conditioning system Careful attention should be paid when the pipeline connection to the outdoor unit is made Try to avoid curves as much as possible as hardening or cracks may occur to the copper pipes Suitable wrenches should be used when the pipeline connection is done so as to ensu...

Page 10: ...ure valve on the manifold then stop the vacuum pump 3 Disconnect the service hoses then fit the cap to the charging valve 4 Remove the blank caps then fully open the spindles on the 2 way and 3 way valves with a service valve wrench 5 Tighten the blank caps on the 2 way and 3 way valves according to the previous torque Table 1 ADDING REFRIGERANT Refrigerant must be added if the piping measures mor...

Page 11: ...2 Align the joint counter of the connecting pipe with the proper indoor and outdoor joint conic surfaces tightening the connecting nut manually Then make is secure with a wrench as shown in drawing according to the torque Table on page 10 3 Remove the two valve core caps from the outdoor unit 4 Turn the high and low pressure valve cores with a socket wrench then tighten the two valve core caps of ...

Page 12: ...ick cable couplers after the disassebly of the outdoor unit 3 Use a press plate to fix the wires firmly into place then reinstall the connection panel 4 Option steps If present in the unit you should connect the indoor wire connector with the outdoor probe wire connector for defrosting WARNING Do not connect the wires the wrong way around otherwise malfunction or damaging the unit can occur The ap...

Page 13: ... wall to prevent rain water from entering and from air drafts TEST RUNNING Connect units to power then check that the function selection keys on the remote control are working correctly Check that the room temperature adjustments and timer settings are working correctly Check that the drainage system is smooth and operational Check for any abnormal noises vibrations or smells Check for any leakage...

Page 14: ... itself place the unit with vibration proof pads not supplied between the unit and the fittings Choose the place where hot air and operation noise from the outlet of the outdoor unit does not annoy neighbours Things left near the outlet and inlet of the outdoor unit may cause malfunction or increased operation noise If irregular sound is heard during operation contact our customer support centre I...

Page 15: ...iour Defrost Indication 1 flash per second dF or a Heating icon Room Temperature Sensor Fault 1 flash per second E2 Coil Temperature Sensor 1 flash per 8 seconds E3 External Feedback Fault 7 flashes per 8 seconds E7 Outdoor Tube Temperature Sensor Faults 4 flashes per 8 seconds E1 EEPROM Communication failures 6 flashes per 8 seconds E6 Outside Temperature exceeds operational range 1 flash per sec...

Page 16: ...ility 28 32 m Rated Voltage and Frequency 220 240V AC 50Hz Ingress Protection OUTDOOR UNIT IP24 Net Weight INDOOR UNIT 14 kg OUTDOOR UNIT 40 kg Max Pressure DISCHARGE 4 2 MPa SUCTION 1 3 MPa Refrigerant Type TYPE R410A QUANTITY 1420 g Noise Level INDOOR UNIT 42 46 dB A OUTDOOR UNIT 55 dB A Dimensions INDOOR UNIT mm 296 h x 900 w x 222 d OUTDOOR UNIT mm 605 h x 850 w x 295 d ...

Page 17: ...17 ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...CUSTOMER HELPLINE 1300 296 699 DISTRIBUTED BY AYONZ PTY LTD ...

Reviews: