7. Installation
7.1 Preparation and equipments before installation
1. Please buy following spare parts from your local market before installation
Hung bolts M12, 4 pcs
Drainage pipe PVC
Copper pipe
Adhesive belt (big size) 5 pcs, (small size) 5 pcs
Heat insulation material used to connect copper pipe (PE foam material, its thickness is more than 8mm)
Power cable, electrical wire between indoor and outdoor unit(Must be in accordance with the wire diameter
in the wiring diagram)
2. Beside general implements, other implements are needed when connecting the pipe
Acetylene cylinders, oxygen cylinders (when longer pipe used it should be welded)
One set pipe cut machine. (cut copper pipe)
Refrigerant cans, electronic balance (when longer pipe used additional gas should be charged)
Pressure gauges, pipe clamp, welding torch, 2B silver electrode
Wrench 2 pcs, one of them is with adjustable torque wrench(42N.m,65N.m,100N.mm)
Nitrogen cylinder (in order to prevent oxidation when welding, using Nitrogen to replace the air)
Select installation position of outdoor unit
◇
The site shall be strong enough to bear its weight, prevent noise and vibration.
◇
The site shall be ensured to avoid direct sunshine, if necessary set a Havelock above the outdoor unit.
◇
The site shall be easy to drainage the rain water and the frost water.
◇
The site shall be ensured that the outdoor unit will not be covered by snow LDring the winter season.
◇
The site shall be ensured that the outlet is not facing the strong wind.
◇
The site shall be ensured that outlet air and operation noise will not affect the neighbors’ daily life.
◇
The site shall be ensured that the outdoor unit will not be affected by the garbage and oil mist.
Warning :
If outdoor unit working under such environment which contains oil (including machine oil) salt(marine
areas), sulfide gas (hot springs and oil refinery areas), those substance may lead to the failure work of the
outdoor unit.
Summary of Contents for AL-H12/4R1D
Page 4: ...AUX Light Commercial Air Conditioners T1 50Hz R410a ON OFF 4 1 Nomenclature ...
Page 72: ...AUX Light CAC 50Hz R410A Universal outdoor unit 72 ALMD H18 4R1D ALMD H24 4R1D ...
Page 93: ...AUX Light CAC 50Hz R410A Trouble shooting 93 1366 610 160 438 368 388 940 ...
Page 129: ...AUX Light CAC 50Hz R410A Trouble shooting 129 Outdoor protection phase sequence ...
Page 130: ...AUX Light CAC 50Hz R410A Trouble shooting 130 Cooling high pressure protection ...
Page 131: ...AUX Light CAC 50Hz R410A Trouble shooting 131 Heating high pressure protection ...
Page 132: ...AUX Light CAC 50Hz R410A Trouble shooting 132 Cooling low pressure protection ...
Page 133: ...AUX Light CAC 50Hz R410A Trouble shooting 133 Heating low pressure protection ...
Page 134: ...AUX Light CAC 50Hz R410A Trouble shooting 134 Cooling exhaust temperature protection ...
Page 135: ...AUX Light CAC 50Hz R410A Trouble shooting 135 Heating exhaust temperature protection ...
Page 137: ...AUX Light CAC 50Hz R410A Trouble shooting 137 Sensor failure protection ...
Page 138: ...AUX Light CAC 50Hz R410A Trouble shooting 138 No action after power on ...
Page 139: ...AUX Light CAC 50Hz R410A Trouble shooting 139 Poor effect ...
Page 140: ...AUX Light CAC 50Hz R410A Trouble shooting 140 ...
Page 141: ...AUX Light CAC 50Hz R410A Trouble shooting 141 Abnormal sound or viberation ...
Page 142: ...AUX Light CAC 50Hz R410A Trouble shooting 142 ...
Page 143: ...AUX Light CAC 50Hz R410A Trouble shooting 143 Abnormal odor ...
Page 145: ...AUX Light CAC 50Hz R410A Trouble shooting 145 Air conditioner water leakage ...