AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF
14
Packing Dimension
(W*H*D)
mm
910×910×350
910×910×350
Net Weight
kg
26.5
26.5
Gross Weight
kg
30.5
30.5
Panel
Net Dimension
(W*H*D)
mm
950×950×55
950×950×55
Packing Dimension
(W*H*D)
mm
1000x1000x100
1000x1000x100
Net weight
kg
5
5
Gross weight
kg
7
7
Refrigerant Pipe
Liquid Side
mm
9.52
9.52
Gas Side
mm
19.05
19.05
Max. Refrigerant Pipe
Length
m
50
50
Max. Level Difference
m
30
30
Setting Temperature Range
°C
16~32
16~32
Operation Ambient
Temperature Range
Cooling
°C
-15~49
-15~49
Heating
°C
-15~24
-15~24
Application Area
m
2
56-93
64-107
Connection Wiring
Power Wiring( Indoor)
mm
2
3×1mm
2
3×1mm
2
Power Wiring( Outdoor)
mm
2
5×4mm
2
5×4mm
2
Signal Wiring
mm
2
2×1mm
2
2×1mm
2
Wireless Remote Controller Model Type
YKR-K/001E
YKR-K/001E
Stufing Quantity
20/40/40H
Set
22/50/55
22/50/55
Note:
1. Working condition of the cooling capacity measured: Inside the room DB temperature 27°C,WB
temperature19°C;Outside of the room DB temperature 35°C,WB temperature 24°C;Working condition
of the heating capacity measured:Inside the room DB temperature 20°C,Outside of the room DB
temperature 7°C,WB temperature 6°C.
2. Parameters above are all measured when the connecting pipe is 5 meters.
3. Parameters above may be modified as product improvement. We keep the right to change the product
specifications without prior notice, please take the parameters listed on the nameplate as criterion.
Summary of Contents for AL-H12/4R1D
Page 4: ...AUX Light Commercial Air Conditioners T1 50Hz R410a ON OFF 4 1 Nomenclature ...
Page 72: ...AUX Light CAC 50Hz R410A Universal outdoor unit 72 ALMD H18 4R1D ALMD H24 4R1D ...
Page 93: ...AUX Light CAC 50Hz R410A Trouble shooting 93 1366 610 160 438 368 388 940 ...
Page 129: ...AUX Light CAC 50Hz R410A Trouble shooting 129 Outdoor protection phase sequence ...
Page 130: ...AUX Light CAC 50Hz R410A Trouble shooting 130 Cooling high pressure protection ...
Page 131: ...AUX Light CAC 50Hz R410A Trouble shooting 131 Heating high pressure protection ...
Page 132: ...AUX Light CAC 50Hz R410A Trouble shooting 132 Cooling low pressure protection ...
Page 133: ...AUX Light CAC 50Hz R410A Trouble shooting 133 Heating low pressure protection ...
Page 134: ...AUX Light CAC 50Hz R410A Trouble shooting 134 Cooling exhaust temperature protection ...
Page 135: ...AUX Light CAC 50Hz R410A Trouble shooting 135 Heating exhaust temperature protection ...
Page 137: ...AUX Light CAC 50Hz R410A Trouble shooting 137 Sensor failure protection ...
Page 138: ...AUX Light CAC 50Hz R410A Trouble shooting 138 No action after power on ...
Page 139: ...AUX Light CAC 50Hz R410A Trouble shooting 139 Poor effect ...
Page 140: ...AUX Light CAC 50Hz R410A Trouble shooting 140 ...
Page 141: ...AUX Light CAC 50Hz R410A Trouble shooting 141 Abnormal sound or viberation ...
Page 142: ...AUX Light CAC 50Hz R410A Trouble shooting 142 ...
Page 143: ...AUX Light CAC 50Hz R410A Trouble shooting 143 Abnormal odor ...
Page 145: ...AUX Light CAC 50Hz R410A Trouble shooting 145 Air conditioner water leakage ...