AUX-Light CAC 50Hz R410A
Sensor resistance table
156
14
7.779
55
1.722
95
0.530
15
7.464
56
1.667
96
0.726
16
7.164
57
1.614
97
0.502
17
6.877
58
1.563
98
0.489
18
6.603
59
1.724
99
0.476
19
6.342
60
1.466
100
0.464
20
6.092
Exhaust temperature sensor 6.339K3954
Exhaust temperature sensor R80
:
6.339KΩ±1% B25/80=3954K±1%
T [
℃
]
Rmin [KΩ]
T [
℃
]
Rmin [KΩ]
T [
℃
]
Rmin [KΩ]
T [
℃
]
Rmin [KΩ]
-20
440.7
20
60.42
60
12.32
100
3.377
-19
417.0
21
57.79
61
11.89
101
3.279
-18
394.7
22
55.29
62
11.48
102
3.184
-17
373.7
23
52.91
63
11.08
103
3.093
-16
353.9
24
50.65
64
10.70
104
3.003
-15
335.2
25
48.49
65
10.34
105
2.918
-14
317.7
26
46.44
66
9.992
106
2.836
-13
301.2
27
44.49
67
9.652
107
2.755
-12
285.6
28
42.64
68
9.328
108
2.678
-11
271.0
29
40.88
69
9.017
109
2.603
-10
257.1
30
39.19
70
8.717
110
2.530
-9
244.0
31
37.59
71
8.428
111
2.460
-8
231.7
32
36.06
72
8.152
112
2.392
-7
220.0
33
34.59
73
7.885
113
2.326
-6
209.0
34
33.21
74
7.628
114
2.262
-5
198.6
35
31.88
75
7.381
115
2.201
-4
188.7
36
30.60
76
7.143
116
2.141
-3
179.4
37
29.39
77
6.914
117
2.083
-2
170.7
38
28.23
78
6.693
118
2.026
-1
162.4
39
27.13
79
6.480
119
1.972
0
154.5
40
26.07
80
6.276
120
1.920
1
147.1
41
25.06
81
6.075
121
1.868
2
140.0
42
24.09
82
5.881
122
1.819
3
133.3
43
23.17
83
5.694
123
1.772
4
127.1
44
22.29
84
5.514
124
1.725
5
121.1
45
21.44
85
5.340
125
1.680
6
115.4
46
20.64
86
5.175
126
1.636
7
109.9
47
19.86
87
5.014
127
1.594
8
104.9
48
19.13
88
4.859
128
1.552
9
100.0
49
18.42
89
4.711
129
1.513
10
95.43
50
17.74
90
4.567
130
1.475
Summary of Contents for AL-H12/4R1D
Page 4: ...AUX Light Commercial Air Conditioners T1 50Hz R410a ON OFF 4 1 Nomenclature ...
Page 72: ...AUX Light CAC 50Hz R410A Universal outdoor unit 72 ALMD H18 4R1D ALMD H24 4R1D ...
Page 93: ...AUX Light CAC 50Hz R410A Trouble shooting 93 1366 610 160 438 368 388 940 ...
Page 129: ...AUX Light CAC 50Hz R410A Trouble shooting 129 Outdoor protection phase sequence ...
Page 130: ...AUX Light CAC 50Hz R410A Trouble shooting 130 Cooling high pressure protection ...
Page 131: ...AUX Light CAC 50Hz R410A Trouble shooting 131 Heating high pressure protection ...
Page 132: ...AUX Light CAC 50Hz R410A Trouble shooting 132 Cooling low pressure protection ...
Page 133: ...AUX Light CAC 50Hz R410A Trouble shooting 133 Heating low pressure protection ...
Page 134: ...AUX Light CAC 50Hz R410A Trouble shooting 134 Cooling exhaust temperature protection ...
Page 135: ...AUX Light CAC 50Hz R410A Trouble shooting 135 Heating exhaust temperature protection ...
Page 137: ...AUX Light CAC 50Hz R410A Trouble shooting 137 Sensor failure protection ...
Page 138: ...AUX Light CAC 50Hz R410A Trouble shooting 138 No action after power on ...
Page 139: ...AUX Light CAC 50Hz R410A Trouble shooting 139 Poor effect ...
Page 140: ...AUX Light CAC 50Hz R410A Trouble shooting 140 ...
Page 141: ...AUX Light CAC 50Hz R410A Trouble shooting 141 Abnormal sound or viberation ...
Page 142: ...AUX Light CAC 50Hz R410A Trouble shooting 142 ...
Page 143: ...AUX Light CAC 50Hz R410A Trouble shooting 143 Abnormal odor ...
Page 145: ...AUX Light CAC 50Hz R410A Trouble shooting 145 Air conditioner water leakage ...