AUX-Light CAC 50Hz R410A
Controller
151
MODE button
:Select mode , push the button one time, then the operation modes will change in turn as
Auto-Cooling-Dehumidify-Heating
TEMP + button
and
TEMP - button
: Temperature adjustment range: 16~32
FAN button
: Change the fan speed will change in turn as: Low-Medium-High-Auto
SWING button
: Press this button for the first time when operation, it will start the swing function. Push the
button for the second time, cancel the swing function. (The function is available matched with the
concerned unit)
TIMER/CLOCK button
:
Clock Setting:
Normally display the clock set currently (display 12:00 for the first electrifying or resetting).
When press the button for 5 seconds, the time display zone will flicker, then press
【
+
】
and
【
-
】
button
and to adjust hour that uses 12-
hour clock including “A.M.” and “P.M.” time;press the button again to
complete the setting.
Timer setting:
Press the button to set TIMER ON/OFF , press the button then “ON” will flicker on the
display screen. then press
【
+
】
and
【
-
】
button and to adjust hour that uses 12-hour clock including
“A.M.” and “P.M.” time;press the button again to complete the setting. The “OFF” setting is the same
methods.
Remark: When setting functions such as mode, temperature, air port and air velocity, display
screen displays all presetting parameters and remains constant; after reaching presetting time,
air conditioner will automatically start as per presetting state.
After setting timing ON and OFF function, pressing button of
【
Timer/Clock
】
can cancel timing
setting.
SLEEP button
:
1. Press the button to the sleeping indicator light of indoor unit flashes on;
2. After the setting of sleeping mode,the cooling operation enables the set temperature to increase 1
℃
after 1 hour and another 1
℃
auto matically after 1hour.
3. After the setting of sleeping mode,the heating operation enables the set temperature to drop 2
℃
after
1 hour and another 2
℃
auto matically after 1hour.
4. The air condition runs in sleeping mode for 7hours and stops automatically.
Remark:
Press the mode or ON/OFF button,the remote controller clears sleeping mode away.
SCREEN button
:Press the button to let the LCD display working or not by pressing the button.
Summary of Contents for AL-H12/4R1D
Page 4: ...AUX Light Commercial Air Conditioners T1 50Hz R410a ON OFF 4 1 Nomenclature ...
Page 72: ...AUX Light CAC 50Hz R410A Universal outdoor unit 72 ALMD H18 4R1D ALMD H24 4R1D ...
Page 93: ...AUX Light CAC 50Hz R410A Trouble shooting 93 1366 610 160 438 368 388 940 ...
Page 129: ...AUX Light CAC 50Hz R410A Trouble shooting 129 Outdoor protection phase sequence ...
Page 130: ...AUX Light CAC 50Hz R410A Trouble shooting 130 Cooling high pressure protection ...
Page 131: ...AUX Light CAC 50Hz R410A Trouble shooting 131 Heating high pressure protection ...
Page 132: ...AUX Light CAC 50Hz R410A Trouble shooting 132 Cooling low pressure protection ...
Page 133: ...AUX Light CAC 50Hz R410A Trouble shooting 133 Heating low pressure protection ...
Page 134: ...AUX Light CAC 50Hz R410A Trouble shooting 134 Cooling exhaust temperature protection ...
Page 135: ...AUX Light CAC 50Hz R410A Trouble shooting 135 Heating exhaust temperature protection ...
Page 137: ...AUX Light CAC 50Hz R410A Trouble shooting 137 Sensor failure protection ...
Page 138: ...AUX Light CAC 50Hz R410A Trouble shooting 138 No action after power on ...
Page 139: ...AUX Light CAC 50Hz R410A Trouble shooting 139 Poor effect ...
Page 140: ...AUX Light CAC 50Hz R410A Trouble shooting 140 ...
Page 141: ...AUX Light CAC 50Hz R410A Trouble shooting 141 Abnormal sound or viberation ...
Page 142: ...AUX Light CAC 50Hz R410A Trouble shooting 142 ...
Page 143: ...AUX Light CAC 50Hz R410A Trouble shooting 143 Abnormal odor ...
Page 145: ...AUX Light CAC 50Hz R410A Trouble shooting 145 Air conditioner water leakage ...