the room;
◇
In order to facilitate maintenance and repair, there should be certain distance between indoor unit
and obstacles;
◇
Refrigerant R22 is used for this unit, which is non-flammable and non-toxic gas. As the proportion of
refrigerant is bigger than air, so if it leaks the gas will be filled on the ground. Therefore, if the units
mounted on a closed room there must be good ventilation to prevent suffocation. In case of leakage
of refrigerant, units should immediately stop running, and contact with maintenance personnel in time.
There must be no fire at the site, because the refrigerant will turn to harmful gas when get to the fire.
7.3 The distance between indoor unit and obstacle
7.4 Indoor unit suspension
◇
Select the suspension foundation
The suspension foundation is a structure of either wooden
frame orreinforced concrete. It must be firm and reliable to
bearat least 4 times.
◇
weight of itself and capable of bearing vibration for long periods;
Fixing of suspension foundation
Fix the suspension bolts either as shown in the picture or by a
steel or wooden bracket;
◇
Adjust the relative positions of the suspension hooks to ensure
the indoorunit is level in all directions. Use a spirit level to ensure this,
otherwise water leakage, air leakage etc. will be resulted;
◇
Tighten the nuts and ensure that the hooks are tightly connected to the nuts and shims,
andthere is no phenomenon of virtual hanging;
◇
After the unit is installed ensure it is secure and does not shake or sway.
7.5 Duct pipeline installation
Using canvas to connect between indoor unit and duct pipeline, in order to save unnecessary vibration,
as to the detail connection method please refer to the following picture.
Summary of Contents for AL-H12/4R1D
Page 4: ...AUX Light Commercial Air Conditioners T1 50Hz R410a ON OFF 4 1 Nomenclature ...
Page 72: ...AUX Light CAC 50Hz R410A Universal outdoor unit 72 ALMD H18 4R1D ALMD H24 4R1D ...
Page 93: ...AUX Light CAC 50Hz R410A Trouble shooting 93 1366 610 160 438 368 388 940 ...
Page 129: ...AUX Light CAC 50Hz R410A Trouble shooting 129 Outdoor protection phase sequence ...
Page 130: ...AUX Light CAC 50Hz R410A Trouble shooting 130 Cooling high pressure protection ...
Page 131: ...AUX Light CAC 50Hz R410A Trouble shooting 131 Heating high pressure protection ...
Page 132: ...AUX Light CAC 50Hz R410A Trouble shooting 132 Cooling low pressure protection ...
Page 133: ...AUX Light CAC 50Hz R410A Trouble shooting 133 Heating low pressure protection ...
Page 134: ...AUX Light CAC 50Hz R410A Trouble shooting 134 Cooling exhaust temperature protection ...
Page 135: ...AUX Light CAC 50Hz R410A Trouble shooting 135 Heating exhaust temperature protection ...
Page 137: ...AUX Light CAC 50Hz R410A Trouble shooting 137 Sensor failure protection ...
Page 138: ...AUX Light CAC 50Hz R410A Trouble shooting 138 No action after power on ...
Page 139: ...AUX Light CAC 50Hz R410A Trouble shooting 139 Poor effect ...
Page 140: ...AUX Light CAC 50Hz R410A Trouble shooting 140 ...
Page 141: ...AUX Light CAC 50Hz R410A Trouble shooting 141 Abnormal sound or viberation ...
Page 142: ...AUX Light CAC 50Hz R410A Trouble shooting 142 ...
Page 143: ...AUX Light CAC 50Hz R410A Trouble shooting 143 Abnormal odor ...
Page 145: ...AUX Light CAC 50Hz R410A Trouble shooting 145 Air conditioner water leakage ...