PR20.0 AIR CLEANER USERS MANUAL 

 

READ AND SAVE THESE INSTRUCTIONS 

Pure n Natural Systems, Inc. recommends that a licensed electrician or licensed contractor 

install units. 

 

WARNINGS: 

 

1.

 

Always unplug or disconnect the air cleaner from power supply before servicing. 

2.

 

To reduce the risk of electric shock or injury to persons, do not expose to water or rain, 
do not use in a window. 

3.

 

Do not use this fan with any solid state speed control device. 

 

FILTER CHANGING: 
 

Pre Filter   

 

 

Replace every 3 to 4 weeks. 

18 pound Carbon V-Bank Filter 

Replace at least every 8 to 12 months. 

H.E.P.A. Filter 

 

 

Replace at least every 12 months. 

 

Step 1.

 The 

Pre Filter

 is located behind the intake door (service door). The Pre Filter is a blue and 

white polyester, pre-tack filter. The intake door is located closest to the HI/OFF/LO switch on the 
face of the system. Unclip the two latches on the intake door and the door will swing down. The 
Pre Filter is the first filter behind the intake door. Peel away dirty Pre Filter and discard. Install 
the new Pre filter with the white side out. Close door. 

DO NOT WASH PRE FILTERS. 

 

Step 2. 

 The 

carbon filter

 is located behind the Pre Filter. Follow Pre Filter changing instructions 

from Step 1. Remove Carbon Filter, discard and replace with new Carbon Filter. 

DO NOT WASH CARBON FILTERS. 

 

Step. 3.

  Remove the adjustable louver door. Remove the H.E.P.A. Bar.  The 

H.E.P.A. Filter

 is a 

pleated media surface with a metal frame. Slip the H.E.P.A. Filter out of the system, discard and 
replace with new H.E.P.A. Filter. 

DO NOT WASH H.E.P.A. FILTER. 

 

 

Filter maintenance may vary according to each situation. 

 
 

For any questions, please contact our customer service department at 

1-800-237-9199

 
 
 
 
 
 
 

Summary of Contents for PR20.0

Page 1: ...k filter The intake door is located closest to the HI OFF LO switch on the face of the system Unclip the two latches on the intake door and the door will swing down The Pre Filter is the first filter behind the intake door Peel away dirty Pre Filter and discard Install the new Pre filter with the white side out Close door DO NOT WASH PRE FILTERS Step 2 The carbon filter is located behind the Pre F...

Page 2: ...system will fit into either one 2 x 4 or two 2 x 2 tiles Step 4 A system being installed into a drop ceiling that has joints steel girders or exposed beams above can be hung without the eye lags see step 5 At least one eye lag will be needed if your system is being installed into a ceiling that is solid above see step 6 Step 5 Locate either a joist girder or beam that is directly above the tile wh...

Page 3: ... grid work of the drop ceiling After you have adjusted the weight of the system on the grid work then loop the wire and twist tightly Step 7 After the system is installed put your H E P A filter back into the system Make sure the H E P A filter is snug Replace the H E P A bar and the adjustable louver door For any questions please contact our customer service department at 1 800 237 9199 ...

Page 4: ...M Installation Options Flushmount fits into 2 2 x 2 ceiling tiles or 1 2 x 4 ceiling tile Dimensions 46 1 2 L x 23 3 4 W x 17 H Cabinet Construction Aluminum Shipping Weight 135 lbs Electrical 9 2 amps 120V Power Cord 10 long 3 prong grounded plug Three Filter System Includes 1 Year Supply of Filters 1 6 HEPA Filter 1 6 18 lb Carbon V Bank Filter 12 1 2 Pre Filters Warranty All Systems carry a lif...

Reviews: