Chapter 3: Monochrome Terminals
ATS Setup Mode
MANU-MAXIMUS-02
Maximus Reference Manual
3-25
Revision-02
14. Next the terminal displays the
Terminal Name
parameter that enables you to
set a unique up-to-20 character administrative name for the terminal. The
default name is “ATS” plus the terminal serial number (e.g.,
ATS000001
).
Press the
enter
key to accept the displayed name or press the
clear
key then
use the numeric keys and the
F2
to change the name. The F2 key toggles the
active character (most recently typed) as listed in
to Character Mapping,” on page 3-11
15. Next the terminal displays the
Append TCP Data with EOT
parameter (the
default is
Yes
).
Press the
enter
key to accept the displayed selection (
Yes
or
No
) or press the
clear
key to toggle between
Yes
and
No
for support of end-of-transmission
(EOT) data. If you choose
Yes
, the terminal appends an ASCII EOT character
(04
16
) to each transaction record sent to the host. Press the
enter
key when the
terminal displays the desired selection to save it.
The terminal returns to the
Setup Password
prompt.
Terminal Name:
At this time the terminal does not save any changes to the
Terminal Name
. If you make any
changes the terminal reverts to the default
Terminal Name
after a re-boot. Use the
following procedure and description for reference/future purposes only.
NOTE:
Append TCP Data with
EOT: No
Set
Append TCP Data with EOT
to
No
unless your communication software or
networking software specifically support EOT (End Of Transmission).
If you set this to
Yes
and EOT is unsupported, the terminal could behave unpredictably,
including not responding to input.
CAUTION