234
DISPLAY FIXED RANGE (>6% OF RANGE)
Touch Current Display (DC Only)
Range 1
0.0uA ~ 32.0uA, DC
Resolution
0.1uA
Base Accuracy
DC : ±(2% of r 3counts)
(>10uA)
Range 2
7.8uA ~ 130.0uA, DC
Resolution
0.1uA
Base Accuracy
DC : ±(2% of r 3counts)
(>10uA)
Range 3
31.5uA ~ 525.0uA, DC
Resolution
0.1uA
Base Accuracy
DC : ±(2% of r 3counts)
(>10uA)
Range 4
126.0uA ~ 999.9uA, 1000uA ~
2100uA, DC
Resolution
1uA
Base Accuracy
DC : ±(2% of r 3counts)
(>10uA)
Range 5
504uA ~ 999.9uA, 1000uA ~ 8400uA,
DC
Resolution
1uA
Base Accuracy
DC : ±(2% of r 3counts)
(>10uA)
Range 6
600uA ~ 8399uA, 8.40mA ~ 10.00mA,
DC
Resolution
1uA, 0.01mA
Base Accuracy
DC : ±5% of reading (0.01mA -
10.00mA )
DISPLAY FIXED RANGE (<6% OF RANGE)
Touch Current Display (DC Only)
Range 1
N/A
Resolution
N/A
Additional Error
N/A
Range 2
0.0uA ~ 7.8uA, DC
Summary of Contents for OMNIA II 8204
Page 8: ...2 This Page Intentionally Left Blank ...
Page 87: ...81 conditions The different combinations are represented in the table below ...
Page 91: ...85 ...
Page 92: ...86 ...
Page 139: ...133 7 128 Power On PROMPT ESR ESE STB SPOLL SRE ESE SRE ...
Page 142: ...136 ...
Page 156: ...150 appear on the display ...
Page 169: ...163 Print Report Example ...
Page 181: ...175 ...