is not installed. If the POTs or Wireless modem cards are not installed, changing the settings will have no effect on
the SiteBoss's functionality.
SiteBoss 571 - Modem Settings
A) Dialup Modem
B) Wireless Modem
This option brings up a menu for configuring the settings for an optional POTs modem card.
This option will bring up a menu for configuring an optional wireless modem card.
Dialup Modem
The following is a top level settings configuration overview for the optional Dialup POTs modem card. For
additional information see the
on Asentria Product Information Portal or contact
CAUTION
–
To reduce the risk of
fire, use only No. 26 AWG or larger telecommunication line cord.
ATTENTION
–
Pour réduire les risques d’incendie, utilizer uniquement des conducteurs de
télécommunications 26 AWG au de section supérleure.
SiteBoss 571 - Dialup Modem Settings
A) Data Format [8N1]
B) Duplex [FULL]
C) Init String [ATM1]
D) Inactivity Timeout [0]
E) Upon Modem Connect Go Directly To [LOGIN]
F) TAP Init String [ATM0]
G) TAP Uses 8N1 Data/Parity/Stop [OFF]
H) Caller ID Security [OFF]
Data Format
This option toggles settings for word length, parity, and stop bit settings. The available options are: 8N1, 7E1,
7O1, and 7N1. Default setting is 8N1.
Duplex
Duplex sets the echo settings for the modem command processor. Full duplex causes the S571 to echo all
characters sent to the remote device. Half duplex turns off character echo. The default setting is FULL.
Init String
This option sets the user-defined modem initialization string. This string is sent to the modem before important
factory modem initialization settings, so certain settings in this init string may be overridden. The default setting is
ATM1. (Maximum length 126 chars)
Inactivity Timeout
This selection sets the number of minutes (0
– 255) to wait before disconnecting an idle modem connection. A
setting of 0 means the connection will never automatically expire. The default setting is 0.
Upon Modem Connect Go Directly To
This menu option toggles through a list of actions to control what a user sees directly after connecting via modem.
LOGIN requires the user to login with username and password, and will then take them to a command prompt. A
serial port (I/O1, I/O2, etc.) redirects a modem user directly to that serial port upon connecting. In Passthrough
mode, the command processor of the S571 is transparent. The default setting is LOGIN.