Construction
and function of the sprayer boom
UF02 BAG00225.3 09.22
97
6.2 Q-plus
boom
Overview – Q-plus boom
(1) Boom carrier frame for sprayer boom height
adjustment
(2) Spray lines
(3) Boom centre section
(4) Transport locking for locking the folded-in
sprayer boom in its transport position to pre-
vent it from folding out unintentionally – un-
locked in the above example
(5) Lockable swing compensation
(6) Tension springs for parallel boom alignment.
(7) Shock absorber
(8) Flow meter for determining the spray rate
[l/ha] (only with quantity regulation)
(9) Return flow meter for determining how much
spray liquid is to be conveyed back into the
spray liquid tank (Control terminal only)
(10) Motor valves for switching the part width sec-
tions on and off (control unit)
(11) Bypass valve
(12) Pressure connection for the spraying-pres-
sure pressure gauge
(13) Pressure relief, reduces excess pressure in
the spray lines after a part width section is
switched off
Summary of Contents for UF 1002
Page 20: ...General safety instructions 20 UF02 BAG00225 3 09 22 Super S boom...
Page 21: ...General safety instructions UF02 BAG00225 3 09 22 21 Q Plus boom...
Page 217: ...Liquid circuit UF02 BAG00225 3 09 22 217 Part width section control...
Page 218: ...Liquid circuit 218 UF02 BAG00225 3 09 22 Single nozzle control Flushing water pump...
Page 219: ...Liquid circuit UF02 BAG00225 3 09 22 219 Single nozzle control FlowControl...
Page 223: ...Spray table UF02 BAG00225 3 09 22 223...
Page 232: ......