Commissioning
UF02 BAG00225.3 09.22
125
(1) Open-Center hydraulic system with con-
stant flow pump (gear pump) or setting
pump.
Select setting B.
Setting pump: Set the maximum required oil
quantity on the tractor control unit. If the oil
quantity is insufficient, correct functioning of
the implement cannot be ensured.
(2) Load-Sensing hydraulic system (pressure-
and flow-regulated setting pump) with direct
load sensing pump connection and LS set-
ting pump.
Select setting A
(3) Load-Sensing hydraulic system with con-
stant flow pump (gear pump).
Select setting A
(4) Closed-Center hydraulic system with pres-
sure-regulated setting pump.
Select setting B
Risk of overheating of the hydraulic system:
the Closed-Center hydraulic system is less
suitable for the operation of hydraulic mo-
tors.