Using the machine
UF02 BAG00225.3 09.22
167
11.8.1 Spraying out the diluted residual quantity at the end of spraying operations
1. Switch off sprayers on the control terminal.
2. Run the pump.
3. Dilute the residual quantity with 10 times the amount of flushing
water.
4. Switch of the agitators.
5. Switch on sprayers on the control terminal.
If possible, first spray out the undiluted spray liquid from the
spray line on an untreated remaining area.
Spray out the diluted residual quantity on the treated area.
Keep flushing the diluted residues until air escapes from the
nozzles.
6. Switch off sprayers on the control terminal.
7. Cleaning the field sprayer.
When spreading residue, observe the maximum permissible applica-
tion quantity of the agent on areas already treated.
11.8.2 Emptying the spray liquid tank using the pump
1. Couple a suitable emptying hose from the
external tank to the implement-side empty-
ing connection.
2.
Check the posi-
tion of the suction valve chest
SA
.
3. Pressure valve chest
DA
in position
.
4. Run the pump.
Emptying
procedure
starts.
5. After emptying, pressure valve chest
DA
in
position .
6. Interrupt the pump drive.
7. Uncouple the hose.
The hose is still filled with spray liquid.
FlowControl: Before emptying, pump the contents of the front tank
into the spray liquid tank.
When the spray liquid tank of the sprayer is empty, the front tank
can no longer be emptied.
Summary of Contents for UF 1002
Page 20: ...General safety instructions 20 UF02 BAG00225 3 09 22 Super S boom...
Page 21: ...General safety instructions UF02 BAG00225 3 09 22 21 Q Plus boom...
Page 217: ...Liquid circuit UF02 BAG00225 3 09 22 217 Part width section control...
Page 218: ...Liquid circuit 218 UF02 BAG00225 3 09 22 Single nozzle control Flushing water pump...
Page 219: ...Liquid circuit UF02 BAG00225 3 09 22 219 Single nozzle control FlowControl...
Page 223: ...Spray table UF02 BAG00225 3 09 22 223...
Page 232: ......