Cleaning, maintenance and repairs
UF02 BAG00225.3 09.22
195
14.6.7 Clean / exchange the filter in the hydraulic plug
Not with Profi-folding.
The hydraulic plugs are equipped with a filter (1)
that may block and then have to be cleaned / ex-
changed.
This is the case when the hydraulic functions run
slower.
1. Unscrew the hydraulic plug from the filter
housing.
2. Remove the filter with compression spring.
3. Clean / exchange the filter.
4. Re-fit the filter and compression spring cor-
rectly.
5. Screw back on the hydraulic plug. In doing
so, observe the correct seating of the O-ring
seal.
CAUTION
Danger of injuries from escaping
hydraulic oil at high pressure!
Work on the hydraulic system only in a
depressurized state.