Construction and function of the sprayer boom
106
UF02 BAG00225.3 09.22
DUS pressure circulating system
Part-width section control: Pressure circulating system must generally
be switched off when using drag hoses.
The pressure circulating system
enables the constant circulation of liquid in
the spray line. For these purposes, a suc-
tion port hose (1) is assigned to each part
width section.
enables operation using spray liquid or
flushing water, as desired.
reduces the undiluted residue for all spray
lines to 2 l.
The constant circulation of liquid
enables production of an even spray pattern
right from the start, because spray liquid is
available at every spraying nozzle immedi-
ately after the sprayer boom is switched on,
with no delay.
prevents damage to the spray line.
Line filter for spray lines (optional
The line filter (1) is
installed in the spray lines in each part-
width section (part-width section control).
installed in the spray lines on the left and
right (single nozzle control)
an additional measure to prevent contami-
nation of the spraying nozzles.
Overview of the filter inserts
Filter insert with 50 mesh/inch (blue)
Filter insert with 80 mesh/inch (grey)
Filter insert with 100 mesh/inch (red)
Summary of Contents for UF 1002
Page 20: ...General safety instructions 20 UF02 BAG00225 3 09 22 Super S boom...
Page 21: ...General safety instructions UF02 BAG00225 3 09 22 21 Q Plus boom...
Page 217: ...Liquid circuit UF02 BAG00225 3 09 22 217 Part width section control...
Page 218: ...Liquid circuit 218 UF02 BAG00225 3 09 22 Single nozzle control Flushing water pump...
Page 219: ...Liquid circuit UF02 BAG00225 3 09 22 219 Single nozzle control FlowControl...
Page 223: ...Spray table UF02 BAG00225 3 09 22 223...
Page 232: ......