Cleaning, maintenance and repairs
UF02 BAG00225.3 09.22
193
Common causes for leaking hoses / pipes and connection pieces in-
clude:
missing O-rings or seals
damaged or badly fitting O-rings
brittle or deformed O-rings or seals
foreign
bodies
badly fitting hose clips
14.6.4 Installing and removing hydraulic hose lines
Use
only genuine AMAZONE replacement hoses. These hoses stand
up to chemical, mechanical and thermal loads.
hose clips made from V2A for fitting hoses, as a rule.
When installing and removing hydraulic hose lines, always observe
the following information:
Ensure
cleanliness.
Always install the hydraulic hose lines
to ensure the following in all operating positions
There is no tension, apart from the hose's own weight.
There is no possibility of jolting on short lengths.
External mechanical influences on the hydraulic hose lines
are avoided.
Use appropriate arrangements and fixing to prevent any
scouring of the hoses on components or on each other. If
necessary, secure hydraulic hose lines using protective co-
vers. Cover sharp-edged components.
The approved bending radii may not be exceeded.
When connecting a hydraulic hose line to moving parts, the hose
length must be appropriate so that the smallest approved bend-
ing radius is not undershot over the whole area of movement
and/or the hydraulic hose line is not overtensioned.
Fix the hydraulic hose lines at the specified fixing points. There,
avoid hose clips, which impair the natural movement and length
changes of the hose.
The coating of hydraulic hose lines is not permitted.
Summary of Contents for UF 1002
Page 20: ...General safety instructions 20 UF02 BAG00225 3 09 22 Super S boom...
Page 21: ...General safety instructions UF02 BAG00225 3 09 22 21 Q Plus boom...
Page 217: ...Liquid circuit UF02 BAG00225 3 09 22 217 Part width section control...
Page 218: ...Liquid circuit 218 UF02 BAG00225 3 09 22 Single nozzle control Flushing water pump...
Page 219: ...Liquid circuit UF02 BAG00225 3 09 22 219 Single nozzle control FlowControl...
Page 223: ...Spray table UF02 BAG00225 3 09 22 223...
Page 232: ......