Construction and function of the sprayer boom
102
UF02 BAG00225.3 09.22
6.4
Boom width reduction (option)
With the boom width reduction, one or two booms can remain folded
in during operation depending on the version.
In addition, switch on the hydraulic accumulator (optional) as a colli-
sion protection.
The respective boom part width sections have to be activated in the
on-board computer.
(1) Boom width reduction
(2) Boom width damping, Optional for UF02
(A) Stop tap opened
(B) Stop tap closed
Working with reduced working width
1. Reduce the boom width hydraulically.
2. Close the stop taps for the boom width reduction.
3. Open the stop tap for the boom damping.
4. Deactivate the respective boom part width sections in the on-
board computer.
5. Perform work with reduced working width.
Close the stop tap for the boom damping.
For road transport
For use with full working width
Summary of Contents for UF 1002