Using the machine
152
UF02 BAG00225.3 09.22
11.3.3 Filling the spray liquid tank through the pressure connection
CAUTION
Maximum permitted water pressure: 8 bar
At a filling capacity greater than 500 l/min, keep the lid of the
spray liquid tank open during the filling procedure.
Otherwise, the spray liquid tank can be damaged.
1. Determine the precise water filling quan-
tity (see section "Calculating the filling or re-
fill quantity", Seite 146).
2. Couple the pressure hose with the pressure
connection and the hydrant.
3. Switch tap
FD
in position
4. TwinTerminal:
4.1 Select pressure filling
.
4.2 Enter the target fill level and confirm.
Filling of the spray liquid tank stops auto-
matically as soon as the nominal fill level
has been reached.
5. Flushing in the agents while filling, see
page 154.
6. Interrupt the filling process if flushing is not
possible before the nominal fill level is
reached.
Switch
tap
FD
in position
0
.
7. When the nominal fill level is reached:
Close the supply-side stop tap.
TwinTerminal: Relieve the pressure
hose
Switch
tap
FD
in position
0
.
Uncouple the hose from the filling con-
nection.
The hose is still filled with water.
Summary of Contents for UF 1002
Page 20: ...General safety instructions 20 UF02 BAG00225 3 09 22 Super S boom...
Page 21: ...General safety instructions UF02 BAG00225 3 09 22 21 Q Plus boom...
Page 217: ...Liquid circuit UF02 BAG00225 3 09 22 217 Part width section control...
Page 218: ...Liquid circuit 218 UF02 BAG00225 3 09 22 Single nozzle control Flushing water pump...
Page 219: ...Liquid circuit UF02 BAG00225 3 09 22 219 Single nozzle control FlowControl...
Page 223: ...Spray table UF02 BAG00225 3 09 22 223...
Page 232: ......