Using the machine
162
UF02 BAG00225.3 09.22
11.7.1 Applying the spray liquid
Properly couple the field sprayer to the tractor.
Before starting spraying, check the following machine data on
the operating terminal
the values for the permitted spray pressure range of the
spraying nozzles installed in the sprayer boom.
the value "Pulses per 100m".
Check the indicated spray pressure during spraying operation.
Control terminal / AMASPRAY
+
: Ensure that the indicated spray
pressure does not deviate under any circumstances by more
than
25 % from the target spray pressure given in the spray ta-
ble, e.g. by changing the spray rate using the plus/minus but-
tons. Larger deviations than this from the target spray pressure
make it impossible to achieve the best possible results from your
crop protection measure and cause pollution of the environment.
Decrease or increase the operational speed until you are back
within the permissible spray pressure range for the target spray
pressure.
Never keep spraying until the spray liquid tank is empty (does
not apply at the end of spraying operation). Refill the spray liquid
tank before the fill level reaches approx. 50 litres.
At the end of spraying operation, when the fill level falls below
approx. 50 litres, switch off the agitator.
Example:
Required spray rate:
200 l/ha
Intended operational speed:
8 km/h
Nozzle type:
AI
Nozzle size:
'05'
Permissible pressure range for the
spraying nozzle when fitted:
min. pressure 2 bar
max. pressure 7 bar
Target spray pressure:
3.7 bar
Permissible spray pressure: 3.7 bar
25
%
min. 2.8 bar and max. 4.6 bar
Observe the ISOBUS software operating manual!
Summary of Contents for UF 1002
Page 20: ...General safety instructions 20 UF02 BAG00225 3 09 22 Super S boom...
Page 21: ...General safety instructions UF02 BAG00225 3 09 22 21 Q Plus boom...
Page 217: ...Liquid circuit UF02 BAG00225 3 09 22 217 Part width section control...
Page 218: ...Liquid circuit 218 UF02 BAG00225 3 09 22 Single nozzle control Flushing water pump...
Page 219: ...Liquid circuit UF02 BAG00225 3 09 22 219 Single nozzle control FlowControl...
Page 223: ...Spray table UF02 BAG00225 3 09 22 223...
Page 232: ......