General safety instructions
UF02 BAG00225.3 09.22
23
MD 086
Risk of crushing the entire body due to nec-
essary periods spent under raised, unse-
cured machine parts.
This danger can cause extremely serious and
potentially fatal injuries.
Before spending time in the danger area under-
neath raised machine parts, secure the raised
parts to prevent them being accidentally lowered.
To do this, use the mechanical support device or
the hydraulic locking device.
MD 094
Danger from electric shock or burns due to
unintentional contact with electric transmis-
sion lines or from approaching high-voltage
transmission lines without authorisation.
These dangers can cause extremely serious and
potentially fatal injuries.
Maintain an adequate safety distance from trans-
mission lines carrying high voltage.
Nominal voltage
Safety distance from
transmission lines
up to 1 kV
over 1 up to 110 kV
over 110 up to 220 kV
over 220 up to 380 kV
1 m
2 m
3 m
4 m
MD 095
Read and follow the operating manual and safety
information before starting up the machine!