General safety instructions
38
UF02 BAG00225.3 09.22
2.16.6 Cleaning, maintenance and repairs
Due to toxic vapours in the spray liquid tank, climbing into the
spray liquid tank is always forbidden.
Repair work in the spray liquid tank must only be carried out by a
specialist workshop!
Only carry out cleaning, maintenance and repair work on the ma-
chine when
the drive is switched off
the tractor engine has come to a complete stop
the ignition key has been removed
the machine connector has been removed from the on-
board computer
Regularly check the nuts and bolts for firm seating and retighten
them as necessary.
Secure the raised machine and/or raised machine parts against
unintentional lowering before performing any cleaning, mainte-
nance or repair work on the machine.
When replacing work tools with blades, use suitable tools and
gloves.
Dispose of oils, greases and filters in the appropriate way.
Disconnect the cable to the tractor generator and battery before
carrying out electrical welding work on the tractor and on at-
tached machines.
Spare parts must meet at least the specified technical require-
ments of
AMAZONEN-WERKE. This is ensured through the use
of genuine AMAZONE spare parts.
When repairing field sprayers which have been used for liquid
fertiliser application with ammonium nitrate / urea solution, ob-
serve the following points:
Residues of ammonium nitrate / urea solutions may form salts by
the evaporation of the water on or in the spray liquid tank. This
produces pure ammonium nitrate and urea. In its undiluted form,
ammonium nitrate is explosive when combined with organic sub-
stances, e.g. urea, and subjected to critical temperatures during
repair work (e.g. welding, grinding, filing).
This danger can be eliminated by thoroughly washing out the
spray liquid tank or the parts intended for repair with water, be-
cause the salt of the ammonium nitrate / urea solution is water-
soluble. For this reason, clean the field sprayer thoroughly with
water before carrying out repair work.
Summary of Contents for UF 1002
Page 20: ...General safety instructions 20 UF02 BAG00225 3 09 22 Super S boom...
Page 21: ...General safety instructions UF02 BAG00225 3 09 22 21 Q Plus boom...
Page 217: ...Liquid circuit UF02 BAG00225 3 09 22 217 Part width section control...
Page 218: ...Liquid circuit 218 UF02 BAG00225 3 09 22 Single nozzle control Flushing water pump...
Page 219: ...Liquid circuit UF02 BAG00225 3 09 22 219 Single nozzle control FlowControl...
Page 223: ...Spray table UF02 BAG00225 3 09 22 223...
Page 232: ......