88
MF-C300A-SF/C500A-SF
4 . Setting the Laser Light Output Schedule
2
Setting ON/OFF for the Modulation Function
(1) Press the "MODU" button to display the MODULATION screen.
(2) Move the cursor to "MODU" and press the ON or OFF key to set whether the
modulation function is valid or not.
At ON, the modulation function set on the MODULATION screen is enabled.
When this function is not used, set OFF.
⇒
For the setting method of the modulation function, refer to "Setting the Modulated
waveform" on page 95.
(3) Press the "X" button to display the SCHEDULE screen.
3
Setting ON/OFF for the Output Schedules for Seam Processing
(1) Press the "SEAM" button to display the SEAM screen.
(2) Press the "SEAM" setting button and set the seam processing output schedule to
ON/OFF.
At ON, the fade function for seam processing set on the SEAM screen is en-
abled. When this function is not used, set OFF.
⇒
For the setting method of the output schedules for seam processing, refer to
"Setting the Output schedules for Seam Processing" on page 91.
⇒
When the laser light output count is set to 9999 by using the "SHOT" setting but-
ton, a laser light is continuously output until the laser stop signal is input and the
fade-in/out function becomes disabled.
(3) Press the "X" button to display the SCHEDULE screen.
Summary of Contents for MF-C300A-SF
Page 20: ......
Page 21: ...Introduction Part...
Page 22: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 42: ......
Page 50: ......
Page 51: ...Operating Part...
Page 52: ......
Page 114: ......
Page 159: ...Maintenance Part...
Page 160: ......
Page 176: ......
Page 177: ...Appendixes...
Page 178: ......