2 . Maintenance of the Laser Oscillator
163
MF-C300A-SF/C500A-SF
Chapter 1 How to Perform Maintenance
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
2 . Maintenance of the Laser Oscillator
Inspecting the Laser Output
Measure and inspect the laser output before and after operation.
It is recommended that the installation space for the laser power meter is secured so
that the laser output from the output unit can be measured.
WARNING
Wear protective glasses . Shield the scattered light because it is also hazardous .
Item required
Laser power meter (FL500A-LP1 manufactured by Ophir is recommended) and pro-
tective glasses
CAUTION
Calibrate the laser power meter every year .
Operating Procedure
(1) Turn on the guide light and adjust the posi-
tion so that the beam diameter becomes
about 2/3 of the diameter at the light receiv-
ing part.
(2) Output the laser light and measure it.
If the output is low, clean or replace the protec-
tive glass of the output unit. For replacement,
refer to the operation manual for the output in
use.
Also check whether there is no change in mea-
surement environment such as ambient tem-
perature, cooling fan of the power meter, and
positional relationship between the output unit
and the power meter.
When the output is not restored, set the laser
output set value ("SET POWER”) again.
Guide light
Power meter
Light receiving part
Standard distance:
About twice the focal dis-
tance of the condensing
lens
Summary of Contents for MF-C300A-SF
Page 20: ......
Page 21: ...Introduction Part...
Page 22: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 42: ......
Page 50: ......
Page 51: ...Operating Part...
Page 52: ......
Page 114: ......
Page 159: ...Maintenance Part...
Page 160: ......
Page 176: ......
Page 177: ...Appendixes...
Page 178: ......