78
MF-C300A-SF/C500A-SF
3 . Changing the Equipment Settings
USER SETTING
How to see the displayed items
: Settable item
Ext .I/O "MONITOR TROU-
BLE" OUTPUT TIMING
(CW)
Sets the output timing of the monitor upper/lower limit check error
in the CW waveform.
SCH. OUTPUT END: Output when output ends (default)
MON. TRB. DETECT: Output when the error occurs (The normal
output signal is turned ON during output until the error occurs.)
OUTPUT Ext .I/O "TROU-
BLE" by REM .I/L ERROR
Sets whether to output the error by the external input/output when
error No.022/EXTERNAL INTERLOCK OPENED occurs.
EXEC: Output (default)
NONE: Not output
AUTO LD POWER CHECK
Not used.
SET-POWER
SYNCHRONIZE
Sets whether to use the set power synchronize setting. Functions
and displays related to the set power synchronize setting are valid
only when this is set to USE.
NONE: Not use (default)
USE: Use
ACTIVE HEAT CONTROL
(OPTION)
Not used. Do not change the setting.
POWER-CORRECT
ASSIST (OPTION)
Sets whether to use the laser output compensation function.
NONE: Not use (default)
USE: Use
X
Returns to the INITIALIZE screen.