MF-C300A-SF/C500A-SF
5 . Monitoring Output
Setting the Output Status Check Screen
In the following, the method of setting the MONITOR screen is explained .
Checking the Measured Energy Value of Laser Light
When laser light is output, the MONITOR screen is automatically displayed and a
measured energy value is displayed. The measured energy value of the last output
laser light can also be checked by the corresponding SCHEDULE number if a regis-
tered SCHEDULE number is entered.
(1) Press the "SCHEDULE" setting button.
Enter the SCHEDULE number by using the "<" and ">" buttons or numeric key-
pad and then press the ENT key.
The measured energy value of the last output laser light and laser light waveform
(green line) are displayed according to the set SCHEDULE.
<Notes>
-
In the CW waveform, the displayed waveform may differ from the actual laser
output due to the sampling period of data for displaying a waveform . When the
modulation function is set in the CW mode, the average power displayed in "AV-
ERAGE" may also differ from the actual laser output power.
Ex .) CW modulation setting: Frequency = 15 Hz, Modulation width = 25%
0
10
20
30
40
50
60
70
0
0.5
1
1.5
2
Controlled waveform
Monitored waveform
Summary of Contents for MF-C300A-SF
Page 20: ......
Page 21: ...Introduction Part...
Page 22: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 42: ......
Page 50: ......
Page 51: ...Operating Part...
Page 52: ......
Page 114: ......
Page 159: ...Maintenance Part...
Page 160: ......
Page 176: ......
Page 177: ...Appendixes...
Page 178: ......