MF-C300A-SF/C500A-SF
2 . Maintenance of the Laser Oscillator
Correcting the Laser Power
This section explains how to correct the lowering of output caused by deterioration of
the optical module.
Perform the following procedure when the rated output cannot obtained even if "SET
POWER" on the SCHEDULE screen is set to the maximum value.
1
Validating the Laser Power Correction Function
(1) Turn OFF the CONTROL keyswitch and turn ON the MAIN POWER switch.
Power is supplied and the POWER lamp comes on.
(2) While the KEY SWITCH CHECK screen is displayed, press the “INITIALIZE” but-
ton, pressing the right
button (red portion in the figure below) of the laser control
-
ler.
⇒
Unless the CONTROL keyswitch is OFF, the KEY SWITCH CHECK screen does
not appear.
The INITIALIZE screen appears.
(3) Press the “USER SETTING” button.
The USER SETTING screen is displayed.
EMERGENCY STOP
LASER