184
MF-C300A-SF/C500A-SF
Timing Chart
Single . . . Operation by laser controller (PANEL CONTROL)
The following diagram shows the lapse of time in the case where the laser light is
output from optical fiber using the laser controller.
*1 5s max.
LD on time.
*2 1s max.
LD output preparation time. In the REPEAT mode, the signal is kept
turned off for certain time after laser output to keep the average
power below the maximum rated output. The signal is not output un-
til a valid schedule is selected.
*3
Time required for the end signal to be output after a laser output
*4
Time required for outputting a signal to indicate whether the laser
energy is within the set upper limit value (HIGH) and lower limit
value (LOW) of monitor output
In *3 and *4, the output time is 20 ms but can be changed to 30 or 40 ms on the CONFIG screen.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Laser beam is projected from
optical fiber
*4
The time set on the CONFIG screen *3
Laser beam is projected from
optical fiber
LD-ON/OFF Input *
LD ON Output
Ready Output
Laser Start Input *
(Laser light)
End Output
Monitor Normal/
Trouble Output
(*: Operation on the user side)
5s max . *1
1s max . *2
Summary of Contents for MF-C300A-SF
Page 20: ......
Page 21: ...Introduction Part...
Page 22: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 42: ......
Page 50: ......
Page 51: ...Operating Part...
Page 52: ......
Page 114: ......
Page 159: ...Maintenance Part...
Page 160: ......
Page 176: ......
Page 177: ...Appendixes...
Page 178: ......