1 . Error Display and How to Take a Measure
173
MF-C300A-SF/C500A-SF
Chapter 2 Inspection and Measure T
o Be T
aken at Occurrence of an Error
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
No .
Contents of error
LD
Alarm
output
Measures
060
POWER FPGA ERROR1
OFF
ON
An error has occurred with the controller unit.
Consult us.
061
POWER FPGA CALC. ERROR
OFF
ON
An error has occurred with the controller unit.
Consult us.
063
064
POWER FPGA ERROR 2
POWER FPGA ERROR 3
OFF
ON
An error has occurred with the controller unit.
Consult us.
067
INTERNAL RS-232C ERROR
OFF
ON
The communication line in the main unit is abnor-
mal.
If there is any noise generation source nearby,
separate it as far as possible or take a preventive
measure for occurrence of noise.
068
INTERNAL RS-232C TIMEOUT
OFF
ON
The communication line in the main unit is abnor-
mal.
If there is any noise generation source nearby,
separate it as far as possible or take a preventive
measure for occurrence of noise.
069
PANEL 485COMM TIMEOUT
OFF
ON
The communication line in the main unit is abnor-
mal.
If there is any noise generation source nearby,
separate it as far as possible or take a preventive
measure for occurrence of noise.
070
BCMD ERROR IN LASER UNIT
OFF
ON
The laser unit could not execute the command.
Consult us.
078
LD-ON TIMEOUT
-
-
A timeout occurred in Oscillator reply “LD ON.”
Check the KEY-SWITCH on attached to the oscilla-
tor. If the KEY-SWITCH is on, consult us.
079
LASER ERROR SIGNAL ERROR
OFF
ON
An oscillator error signal of unknown cause has
been detected.
Consult us.
080
OSCILLATOR NOT READY
OFF
ON
The oscillator has not started normally.
Consult us.
082
ILLEGAL OSCILLATOR SIGNAL
OFF
ON
A signal from the oscillator is abnormal.
Consult us.
163
ILLEGAL WARNING SIGNAL
-
-
An oscillator warning signal of unknown cause has
been detected.
Consult us.
164
LASER STOP2
OFF
ON
The REM. I/L connector circuit is opened.
Eliminate the cause of trouble and close the pin.
165
LD POWER SUPPLY ERROR
OFF
ON
An error has occurred with the LD power supply.
Consult us.
166
LD CURRENT OVERLOAD
OFF
ON
Overcurrent of the LD.
Consult us.
205
206
THERMAL 1 ERROR
THERMAL 2 ERROR
OFF
ON
Abnormal temperature of the internal unit.
After waiting for several minutes, press the TROU-
BLE RESET button.
Summary of Contents for MF-C300A-SF
Page 20: ......
Page 21: ...Introduction Part...
Page 22: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 42: ......
Page 50: ......
Page 51: ...Operating Part...
Page 52: ......
Page 114: ......
Page 159: ...Maintenance Part...
Page 160: ......
Page 176: ......
Page 177: ...Appendixes...
Page 178: ......