3 . Connector Functions
121
MF-C300A-SF/C500A-SF
Chapter 4 Laser Processing by External Input/ Output Signals (EXTERNAL
CONTROL)
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
Pin No .
Description
23
Unused
Do not connect anything.
24
Unused
Do not connect anything.
25
Unused
Do not connect anything.
26
Unused
Do not connect anything.
27
SCHEDULE 1
Select a registered SCHEDULE number by combining schedule
signal inputs 1, 2, 4, 8, 16, 32, 64 and 128.
28
SCHEDULE 2
29
SCHEDULE 4
30
SCHEDULE 8
31
SCHEDULE 16
32
SCHEDULE 32
33
SCHEDULE 64
34
SCHEDULE 128
35
Input COM
Common terminal for input signals.
36
Unused
Do not connect anything.
37
0V
Ground for +24 V DC output.
Output Pins of EXT . I/O (2) Connector
Pin No .
Description
1
24V OUT
Power supply for external I/O.
2
Unused
Do not connect anything.
3
Beam ON
While BEAM is ON, this pin is closed internally.
4
Unused
Do not connect anything.
5
Unused
Do not connect anything.
6
Unused
Do not connect anything.
7
Unused
Do not connect anything.
8
Unused
Do not connect anything.
9
Unused
Do not connect anything.
10
Unused
Do not connect anything.
11
Unused
Do not connect anything.
Summary of Contents for MF-C300A-SF
Page 20: ......
Page 21: ...Introduction Part...
Page 22: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 42: ......
Page 50: ......
Page 51: ...Operating Part...
Page 52: ......
Page 114: ......
Page 159: ...Maintenance Part...
Page 160: ......
Page 176: ......
Page 177: ...Appendixes...
Page 178: ......