4 . Commands
139
MF-C300A-SF/C500A-SF
Chapter 5 Laser Processing by External Communication Control (RS-485 CONTROL)
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
4 . Commands
This section explains the commands that are used to control laser processing
by external communication .
Code Table
The codes for external communication with a personal computer and the text struc-
ture are as follows. For details, refer to "Setting Data" on page 141 to "Reading the
Equipment Name" on page 158.
Control Codes (Hexadecimal Codes)
ACK: 06H NAK: 15H STX: 02H ETX: 03H
BCC (block check code) ... 1-byte horizontal even parity up to ETX excluding STX
Code
Contents
Text structure
W
Setting data
PC to laser
S
T
X
C
H
1
C
H
0
W
L
A
1
L
A
0
S
H
3
S
H
2
S
H
1
S
H
0
D
T
1
D
T
0
: data
E
T
X
B
C
C
Laser to PC
C
H
1
C
H
0
A
C
K
Or
C
H
1
C
H
0
N
A
K
Write data is out of the
setting range or external
communication control is not
performed.
R
Reading data
PC to laser
S
T
X
C
H
1
C
H
0
R
L
A
1
L
A
0
S
H
3
S
H
2
S
H
1
S
H
0
D
T
1
D
T
0
E
T
X
B
C
C
Laser to PC
S
T
X
data
E
T
X
B
C
C
Or
C
H
1
C
H
0
N
A
K
The schedule No. or
data No. is out of the
range.
WS
Setting the
control method,
SCHEDULE
No., etc.
PC to laser
S
T
X
C
H
1
C
H
0
W
S
S
H
3
S
H
2
S
H
1
S
H
0
c
n
t
s
1
s
2
…
s
9
m
o
n
E
T
X
B
C
C
Laser to PC
C
H
1
C
H
0
A
C
K
Or
C
H
1
C
H
0
N
A
K
The specified status cannot
be provided or external
communication control is not
performed.
WD
Setting the
system date
and time
PC to laser
S
T
X
C
H
1
C
H
0
W
D
Y
3
Y
0
M
O
1
M
O
0
D
1
D
0
H
1
H
0
M
I
1
M
I
0
E
T
X
B
C
C
Laser to PC
C
H
1
C
H
0
A
C
K
Or
C
H
1
C
H
0
N
A
K
The specified status cannot
be provided or external
communication control is not
performed.
RS
Reading the
control method,
SCHEDULE
No., etc.
PC to laser
S
T
X
C
H
1
C
H
0
R
S
E
T
X
B
C
C
Laser to PC
S
T
X
C
H
1
C
H
0
S
H
3
S
H
2
S
H
1
S
H
0
c
n
t
s
1
s
2
s
3
…
s
9
m
o
n
r
d
y
E
T
X
B
C
C
RD
Reading the
system date
and time
PC to laser
S
T
X
C
H
1
C
H
0
R
D
E
T
X
B
C
C
Laser to PC
S
T
X
Y
3
Y
2
Y
1
Y
0
M
O
1
M
O
0
D
1
D
0
H
1
H
0
M
I
1
M
I
0
E
T
X
B
C
C
$0
Laser start
command
PC to laser
S
T
X
C
H
1
C
H
0
$
0
E
T
X
B
C
C
Laser to PC
C
H
1
C
H
0
A
C
K
Or
C
H
1
C
H
0
N
A
K
The LD is OFF, trouble
occurs, or external
communication control is not
performed.
…
Summary of Contents for MF-C300A-SF
Page 20: ......
Page 21: ...Introduction Part...
Page 22: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 42: ......
Page 50: ......
Page 51: ...Operating Part...
Page 52: ......
Page 114: ......
Page 159: ...Maintenance Part...
Page 160: ......
Page 176: ......
Page 177: ...Appendixes...
Page 178: ......