112
MF-C300A-SF/C500A-SF
3 . Operating Procedure
⇒
For setting the number of laser light outputs, set it in "SHOT" in the range of 1 to
9999. When 1 is set, a single output is performed.
3
Outputting Laser Light
WARNING
Be sure to put on specified protective glasses during laser light output operation.
Even if you wear them, you may lose your sight if the laser beam enters your eyes
directly through protective glasses .
(1) Press the "STATUS" button to display the STATUS screen.
When Pin No.25 (control switching) of the EXT. I/O (1) connector remains in an
open state, external input signals are disabled and "PANEL CONTROL" is dis-
played in "CONTROL DEVICE."
(2) Adjust the workpiece and output unit positions to set an appropriate work dis-
tance (distance between the workpiece and the output position).
(3) Press the "LD" setting button.
The LD lights up.
(4) Press the “GUIDE” setting button to set it to ON to output guide light.
The “GUIDE” setting button is set to ON and a red dot of guide light appears at
the laser light injecting position. Laser light is injected to the red-dot position.