3 . Operating Procedure
113
MF-C300A-SF/C500A-SF
Chapter 3 Laser Processing by Laser Controller (P
ANEL
CONTROL)
Introduction Part
Installation
and
Preparation
Part
Operating Part
Maintenance Part
Appendixes
(5) Check the laser light irradiation position.
If the point to be worked deviates from the red point of guide light, adjust the po-
sition by moving the output unit or workpiece.
(6) Press the LASER START/STOP button.
Laser light is output.
⇒
Before pressing the LASER START/STOP button, display the SCHEDULE
screen or MONITOR screen and input another registered SCHEDULE number.
With this, laser light is output in the output conditions of this SCHEDULE.
(7) Press the "MON" button to display the MONITOR screen, and check the laser
output energy (J) and average power (W) of the output laser light.
4
Stopping Laser Processing
CAUTION
During a laser light output or for 5 seconds immediately after a laser light output, do
not turn OFF the MAIN POWER switch .
(1) Press the "LD" and "GUIDE" setting buttons on each screen to set them to OFF.
(2) Turn OFF the CONTROL keyswitch.
The key can be pulled out.
(3) Turn OFF the MAIN POWER switch.
The power supply is turned OFF and the POWER lamp goes out.
⇒
Return the key of the CONTROL keyswitch to the laser safety supervisor so that
it can be kept in custody.
Summary of Contents for MF-C300A-SF
Page 20: ......
Page 21: ...Introduction Part...
Page 22: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 42: ......
Page 50: ......
Page 51: ...Operating Part...
Page 52: ......
Page 114: ......
Page 159: ...Maintenance Part...
Page 160: ......
Page 176: ......
Page 177: ...Appendixes...
Page 178: ......